FHWA NBI 2024 Inspection record Public-domain dataset

GENOA AVE

Carrying GENOA AVE over I- 57

0.4 M W IL 1, Cook, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
61 t Inventory load rating Higher than 97% of rated Illinois bridges

GENOA AVE in Cook, Illinois sits above 97% of rated Illinois bridges on inventory load rating (61 t), while its 1968 build year is earlier than 38% of Cook's recorded-year cohort (1,721 bridges).

GENOA AVE in Cook, Illinois is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1968, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:016203000000000

INTERSTATE-ERA · STEEL · MULTI-SPAN · TIED-CTRL · HEAVY-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: GENOA AVE

The GENOA AVE bridge in Cook, Illinois carries GENOA AVE over I- 57. It was built in 1968, making it 58 years old today. It was last reconstructed in 2010, extending its service life. The structure is built primarily of steel continuous and spans 2 sections, stretching 57.5 meters (189 feet) end to end. Daily traffic averages 11,900 vehicles, placing it in the heavily-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How GENOA AVE compares

▲ 25.6
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
1,721
Bridges in Cook · 237 in Poor condition

Age against the county: built in 1968, earlier than 654 of Cook's 1,721 bridges with a recorded construction year (38%), against a county median build year of 1962. This is one of the newer structures in its county.

GENOA AVE 60.6 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

GENOA AVE vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

61 Top 3% higher than 97% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
60.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Cook inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,721 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1968
Last Reconstructed
2010
Material
Steel Continuous
Number of Spans
2
Structure Length
57.5 m (189 ft)
Deck Width
21.6 m (71 ft)
Owner
State Highway Agency
Avg Daily Traffic
11,900 vehicles/day
Structure Number
016203000000000

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether GENOA AVE is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare GENOA AVE against other structures in Cook and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GENOA AVE?

GENOA AVE in Cook, Illinois has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is GENOA AVE inspected?

GENOA AVE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,900 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GENOA AVE is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GENOA AVE?

GENOA AVE has an NBI inventory load rating of 60.6 metric tons.

Who is responsible for maintaining GENOA AVE?

GENOA AVE is owned and maintained by State Highway Agency.

How old is GENOA AVE and does age affect safety?

GENOA AVE was built in 1968, making it 58 years old and last reconstructed in 2010.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.