FHWA NBI 2024 Inspection record Public-domain dataset

FAU-1552 GRMN CH R

Carrying FAU-1552 GRMN CH R over FLAG CREEK

0.03 M W WOLF P10, Cook, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
43 t Inventory load rating Higher than 84% of rated Illinois bridges

FAU-1552 GRMN CH R in Cook, Illinois sits above 84% of rated Illinois bridges on inventory load rating (43 t), while its 1963 build year is earlier than 47% of Cook's recorded-year cohort (1,721 bridges).

FAU-1552 GRMN CH R in Cook, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1963, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 3. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:016306400000000

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · HEAVY-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FAU-1552 GRMN CH R

The FAU-1552 GRMN CH R bridge in Cook, Illinois carries FAU-1552 GRMN CH R over FLAG CREEK. It was built in 1963, making it 63 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 37.2 meters (122 feet) end to end. Daily traffic averages 5,350 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 3/9, substructure at 6/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How FAU-1552 GRMN CH R compares

▲ 7.8
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
1,721
Bridges in Cook · 237 in Poor condition

Age against the county: built in 1963, earlier than 807 of Cook's 1,721 bridges with a recorded construction year (47%), against a county median build year of 1962. This is one of the newer structures in its county.

FAU-1552 GRMN CH R 42.8 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

FAU-1552 GRMN CH R vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

43 Top 16% higher than 84% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
42.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Cook inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,721 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1963
Material
Prestressed Concrete
Number of Spans
3
Structure Length
37.2 m (122 ft)
Deck Width
12.2 m (40 ft)
Owner
County Highway Agency
Avg Daily Traffic
5,350 vehicles/day
Structure Number
016306400000000

Condition Analysis

  • The deck (driving surface) is in poor condition (3/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • At 3/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

FAU-1552 GRMN CH R is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAU-1552 GRMN CH R against other structures in Cook and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAU-1552 GRMN CH R?

FAU-1552 GRMN CH R in Cook, Illinois has a deck rating of 3/9, superstructure rating of 3/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FAU-1552 GRMN CH R inspected?

FAU-1552 GRMN CH R's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,350 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAU-1552 GRMN CH R is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAU-1552 GRMN CH R?

FAU-1552 GRMN CH R has an NBI inventory load rating of 42.8 metric tons.

Who is responsible for maintaining FAU-1552 GRMN CH R?

FAU-1552 GRMN CH R is owned and maintained by County Highway Agency.

How old is FAU-1552 GRMN CH R and does age affect safety?

FAU-1552 GRMN CH R was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.