FHWA NBI 2024 Inspection record Public-domain dataset

EGGLESTON AVENUE

Carrying EGGLESTON AVENUE over AUBURN PARK LAGOON

7800S 430W, Cook, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating Lower than 76% of rated Illinois bridges

EGGLESTON AVENUE in Cook, Illinois sits above 24% of rated Illinois bridges on inventory load rating (32 t), while its 1923 build year is earlier than 95% of Cook's recorded-year cohort (1,721 bridges).

EGGLESTON AVENUE in Cook, Illinois is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1923, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:016650400000000

PRE-1950 · PRESTRESS · SINGLE-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: EGGLESTON AVENUE

The EGGLESTON AVENUE bridge in Cook, Illinois carries EGGLESTON AVENUE over AUBURN PARK LAGOON. It was built in 1923, making it 103 years old today. It was last reconstructed in 1997, extending its service life. The structure is built primarily of prestressed concrete and spans 1 section, stretching 8.2 meters (27 feet) end to end. Daily traffic averages 225 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How EGGLESTON AVENUE compares

▼ 2.6
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
1,721
Bridges in Cook · 237 in Poor condition

Age against the county: built in 1923, earlier than 1,641 of Cook's 1,721 bridges with a recorded construction year (95%), against a county median build year of 1962. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

EGGLESTON AVENUE 32.4 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

EGGLESTON AVENUE vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

32 Top 76% higher than 24% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Cook inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,721 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1923
Last Reconstructed
1997
Material
Prestressed Concrete
Number of Spans
1
Structure Length
8.2 m (27 ft)
Deck Width
10.8 m (35 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
225 vehicles/day
Structure Number
016650400000000

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether EGGLESTON AVENUE is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare EGGLESTON AVENUE against other structures in Cook and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for EGGLESTON AVENUE?

EGGLESTON AVENUE in Cook, Illinois has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is EGGLESTON AVENUE inspected?

EGGLESTON AVENUE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 225 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. EGGLESTON AVENUE is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for EGGLESTON AVENUE?

EGGLESTON AVENUE has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining EGGLESTON AVENUE?

EGGLESTON AVENUE is owned and maintained by City/Municipal Highway Agency.

How old is EGGLESTON AVENUE and does age affect safety?

EGGLESTON AVENUE was built in 1923, making it 103 years old and last reconstructed in 1997.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.