Poor
30 t Inventory load rating Lower than 81% of rated Illinois bridges

FAI 57 NBL in Ford, Illinois sits above 19% of rated Illinois bridges on inventory load rating (30 t), while its 1968 build year is earlier than 82% of Ford's recorded-year cohort (302 bridges).

FAI 57 NBL in Ford, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1968, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:027005300000000

INTERSTATE-ERA · PRESTRESS · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 5 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FAI 57 NBL

The FAI 57 NBL bridge in Ford, Illinois carries FAI 57 NBL over BIG FOUR DITCH. It was built in 1968, making it 58 years old today. The structure is built primarily of prestressed concrete and spans 5 sections, stretching 85.6 meters (281 feet) end to end. Daily traffic averages 10,550 vehicles, placing it in the heavily-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How FAI 57 NBL compares

▼ 5.5
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
302
Bridges in Ford · 19 in Poor condition

Age against the county: built in 1968, earlier than 248 of Ford's 302 bridges with a recorded construction year (82%), against a county median build year of 1981. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

FAI 57 NBL 29.5 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

FAI 57 NBL vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

30 Top 81% higher than 19% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
29.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Ford inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 302 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1968
Material
Prestressed Concrete
Number of Spans
5
Structure Length
85.6 m (281 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
10,550 vehicles/day
Structure Number
027005300000000

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

FAI 57 NBL is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAI 57 NBL against other structures in Ford and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAI 57 NBL?

FAI 57 NBL in Ford, Illinois has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is FAI 57 NBL inspected?

FAI 57 NBL's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 10,550 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAI 57 NBL is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAI 57 NBL?

FAI 57 NBL has an NBI inventory load rating of 29.5 metric tons.

Who is responsible for maintaining FAI 57 NBL?

FAI 57 NBL is owned and maintained by State Highway Agency.

How old is FAI 57 NBL and does age affect safety?

FAI 57 NBL was built in 1968, making it 58 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.