FHWA NBI 2024 Inspection record Public-domain dataset

RESERVATION/FAU251

Carrying RESERVATION/FAU251 over MORGAN CK

2 MI W OF CH 16, Kendall, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
25 t Inventory load rating Lower than 87% of rated Illinois bridges

RESERVATION/FAU251 in Kendall, Illinois sits above 13% of rated Illinois bridges on inventory load rating (25 t), while its 1980 build year is earlier than 70% of Kendall's recorded-year cohort (132 bridges).

RESERVATION/FAU251 in Kendall, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1980, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:047311400000000

LATE-CENTURY · PRESTRESS · SINGLE-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: RESERVATION/FAU251

The RESERVATION/FAU251 bridge in Kendall, Illinois carries RESERVATION/FAU251 over MORGAN CK. It was built in 1980, making it 46 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 12.5 meters (41 feet) end to end. Daily traffic averages 1,150 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How RESERVATION/FAU251 compares

▼ 9.7
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
132
Bridges in Kendall · 16 in Poor condition

Age against the county: built in 1980, earlier than 93 of Kendall's 132 bridges with a recorded construction year (70%), against a county median build year of 1994. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

RESERVATION/FAU251 25.3 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

RESERVATION/FAU251 vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 87% higher than 13% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
25.3 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Kendall inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 132 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1980
Material
Prestressed Concrete
Number of Spans
1
Structure Length
12.5 m (41 ft)
Deck Width
8.2 m (27 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
1,150 vehicles/day
Structure Number
047311400000000

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

RESERVATION/FAU251 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RESERVATION/FAU251 against other structures in Kendall and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RESERVATION/FAU251?

RESERVATION/FAU251 in Kendall, Illinois has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is RESERVATION/FAU251 inspected?

RESERVATION/FAU251's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,150 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RESERVATION/FAU251 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RESERVATION/FAU251?

RESERVATION/FAU251 has an NBI inventory load rating of 25.3 metric tons.

Who is responsible for maintaining RESERVATION/FAU251?

RESERVATION/FAU251 is owned and maintained by Town/Township Highway Agency.

How old is RESERVATION/FAU251 and does age affect safety?

RESERVATION/FAU251 was built in 1980, making it 46 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.