Poor
30 t Inventory load rating Lower than 81% of rated Illinois bridges

CH11 PUMP FACTORY in Lee, Illinois sits above 19% of rated Illinois bridges on inventory load rating (30 t), while its 1960 build year is earlier than 87% of Lee's recorded-year cohort (371 bridges).

CH11 PUMP FACTORY in Lee, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1960, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:052359000000000

INTERSTATE-ERA · CONCRETE · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: CH11 PUMP FACTORY

The CH11 PUMP FACTORY bridge in Lee, Illinois carries CH11 PUMP FACTORY over THREE MILE BRANCH. It was built in 1960, making it 66 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 30.2 meters (99 feet) end to end. Daily traffic averages 250 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How CH11 PUMP FACTORY compares

▼ 5.5
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
371
Bridges in Lee · 45 in Poor condition

Age against the county: built in 1960, earlier than 322 of Lee's 371 bridges with a recorded construction year (87%), against a county median build year of 1982. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

CH11 PUMP FACTORY 29.5 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

CH11 PUMP FACTORY vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

30 Top 81% higher than 19% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
29.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lee inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 371 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1960
Material
Concrete
Number of Spans
3
Structure Length
30.2 m (99 ft)
Deck Width
8.7 m (29 ft)
Owner
County Highway Agency
Avg Daily Traffic
250 vehicles/day
Structure Number
052359000000000

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

CH11 PUMP FACTORY is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CH11 PUMP FACTORY against other structures in Lee and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CH11 PUMP FACTORY?

CH11 PUMP FACTORY in Lee, Illinois has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is CH11 PUMP FACTORY inspected?

CH11 PUMP FACTORY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 250 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CH11 PUMP FACTORY is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CH11 PUMP FACTORY?

CH11 PUMP FACTORY has an NBI inventory load rating of 29.5 metric tons.

Who is responsible for maintaining CH11 PUMP FACTORY?

CH11 PUMP FACTORY is owned and maintained by County Highway Agency.

How old is CH11 PUMP FACTORY and does age affect safety?

CH11 PUMP FACTORY was built in 1960, making it 66 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.