FHWA NBI 2024 Inspection record Public-domain dataset

Indiana Ave/FAU 63

Carrying Indiana Ave/FAU 63 over Trib. Smith Branch

1685 E 1800 N, Livingston, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
18 t Inventory load rating Lower than 97% of rated Illinois bridges

Indiana Ave/FAU 63 in Livingston, Illinois sits above 3% of rated Illinois bridges on inventory load rating (18 t), while its 1948 build year is earlier than 87% of Livingston's recorded-year cohort (579 bridges).

Indiana Ave/FAU 63 in Livingston, Illinois is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1948, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:053326500000000

PRE-1950 · CONCRETE · SINGLE-SPAN · TIED-CTRL · ADT-UNK · LIGHT-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ADT-UNK ADT unknown
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: Indiana Ave/FAU 63

The Indiana Ave/FAU 63 bridge in Livingston, Illinois carries Indiana Ave/FAU 63 over Trib. Smith Branch. It was built in 1948, making it 78 years old today. The structure is built primarily of concrete and spans 1 section, stretching 8.7 meters (29 feet) end to end. Average daily traffic is not reported for this structure. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How Indiana Ave/FAU 63 compares

▼ 17.5
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
579
Bridges in Livingston · 48 in Poor condition

Age against the county: built in 1948, earlier than 504 of Livingston's 579 bridges with a recorded construction year (87%), against a county median build year of 1981. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

Indiana Ave/FAU 63 17.5 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

Indiana Ave/FAU 63 vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

18 Top 97% higher than 3% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
17.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Livingston inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 579 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1948
Material
Concrete
Number of Spans
1
Structure Length
8.7 m (29 ft)
Deck Width
8.4 m (28 ft)
Owner
City/Municipal Highway Agency
Structure Number
053326500000000

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether Indiana Ave/FAU 63 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Indiana Ave/FAU 63 against other structures in Livingston and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Indiana Ave/FAU 63?

Indiana Ave/FAU 63 in Livingston, Illinois has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is Indiana Ave/FAU 63 inspected?

Indiana Ave/FAU 63's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Indiana Ave/FAU 63 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Indiana Ave/FAU 63?

Indiana Ave/FAU 63 has an NBI inventory load rating of 17.5 metric tons.

Who is responsible for maintaining Indiana Ave/FAU 63?

Indiana Ave/FAU 63 is owned and maintained by City/Municipal Highway Agency.

How old is Indiana Ave/FAU 63 and does age affect safety?

Indiana Ave/FAU 63 was built in 1948, making it 78 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.