TR 65A
Carrying TR 65A over I-55/UP RR/W FR RD
LAWNDALE 3.5 N BUS55, Logan, Illinois
Inventory: FHWA NBI 2024 · last ETL August 2026
FHWA NBI record, refreshed with each annual release.
TR 65A in Logan, Illinois sits above 77% of rated Illinois bridges on inventory load rating (40 t), while its 1974 build year is earlier than 50% of Logan's recorded-year cohort (292 bridges).
TR 65A in Logan, Illinois is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1974, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.
NBI record plate
Structure IL:054006200000000
INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-GOOD
- INTERSTATE-ERA 1950–1979
- STEEL Steel
- LONG-SPAN-RUN 4 spans
- TIED-CTRL Tied control
- LOCAL-ADT Local ADT
- STANDARD-LOAD Standard load
- CAT-GOOD Good
Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.
Bridge Snapshot: TR 65A
The TR 65A bridge in Logan, Illinois carries TR 65A over I-55/UP RR/W FR RD. It was built in 1974, making it 52 years old today. The structure is built primarily of steel continuous and spans 4 sections, stretching 152.9 meters (502 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by State Highway Agency.
The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range.
How TR 65A compares
Age against the county: built in 1974, earlier than 146 of Logan's 292 bridges with a recorded construction year (50%), against a county median build year of 1974.
Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).
TR 65A vs every rated Illinois bridge
Inventory load rating (metric tons), FHWA NBI, this state
40 Top 23% higher than 77% of 26,904 bridges
rated Illinois bridges, bucketed by value
Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.
Source FHWA National Bridge Inventory · August 2026
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.
Logan inventory by recorded NBI category
Exclusive Good/Fair/Poor bands across all 292 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.
Structural Details
- Year Built
- 1974
- Material
- Steel Continuous
- Number of Spans
- 4
- Structure Length
- 152.9 m (502 ft)
- Deck Width
- 9.8 m (32 ft)
- Owner
- State Highway Agency
- Avg Daily Traffic
- 100 vehicles/day
- Structure Number
- 054006200000000
Condition Analysis
- • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
- • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
- • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗How to read this record
This page shows what the last federal inspection recorded, not whether TR 65A is safe to cross today. Here is how to use it.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
- Compare TR 65A against other structures in Logan and across Illinois. Illinois bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for TR 65A?
TR 65A in Logan, Illinois has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.
How often is TR 65A inspected?
TR 65A's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. TR 65A is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for TR 65A?
TR 65A has an NBI inventory load rating of 39.5 metric tons.
Who is responsible for maintaining TR 65A?
TR 65A is owned and maintained by State Highway Agency.
How old is TR 65A and does age affect safety?
TR 65A was built in 1974, making it 52 years old.
Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.
Share this inspection record
Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.
Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.