FHWA NBI 2024 Inspection record Public-domain dataset

281ST ST EAST

Carrying 281ST ST EAST over CICERO CREEK

00.47 E OF SR 19, Hamilton, Indiana

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
22 t Inventory load rating Lower than 92% of rated Indiana bridges

281ST ST EAST in Hamilton, Indiana sits above 8% of rated Indiana bridges on inventory load rating (22 t), while its 1979 build year is earlier than 79% of Hamilton's recorded-year cohort (454 bridges).

281ST ST EAST in Hamilton, Indiana is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1979, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IN:2900058

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · DECK-LED · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • DECK-LED Deck-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 281ST ST EAST

The 281ST ST EAST bridge in Hamilton, Indiana carries 281ST ST EAST over CICERO CREEK. It was built in 1979, making it 47 years old today. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 61.0 meters (200 feet) end to end. Daily traffic averages 910 vehicles, placing it in the lower-traffic tier of Indiana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 8/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How 281ST ST EAST compares

▼ 13.5
Load rating vs Indiana average (35.5 t; 19,495 rated)
454
Bridges in Hamilton · 12 in Poor condition

Age against the county: built in 1979, earlier than 358 of Hamilton's 454 bridges with a recorded construction year (79%), against a county median build year of 2002. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

281ST ST EAST 22.0 t
Indiana average (19,495 rated) 35.5 t

Live comparison across Indiana bridges with a recorded inventory load rating (19,495 rated).

281ST ST EAST vs every rated Indiana bridge

Inventory load rating (metric tons), FHWA NBI, this state

22 Top 92% higher than 8% of 19,495 bridges

rated Indiana bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
22.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Hamilton inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 454 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1979
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
61.0 m (200 ft)
Deck Width
8.7 m (29 ft)
Owner
County Highway Agency
Avg Daily Traffic
910 vehicles/day
Structure Number
2900058

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether 281ST ST EAST is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 281ST ST EAST against other structures in Hamilton and across Indiana. Indiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 281ST ST EAST?

281ST ST EAST in Hamilton, Indiana has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is 281ST ST EAST inspected?

281ST ST EAST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 910 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 281ST ST EAST is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 281ST ST EAST?

281ST ST EAST has an NBI inventory load rating of 22.0 metric tons.

Who is responsible for maintaining 281ST ST EAST?

281ST ST EAST is owned and maintained by County Highway Agency.

How old is 281ST ST EAST and does age affect safety?

281ST ST EAST was built in 1979, making it 47 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.