ARBOR ST
Carrying ARBOR ST over HIGHLAND CREEK
00.33 S OF TROY AVE, Marion, Indiana
Inventory: FHWA NBI 2024 · last ETL August 2026
FHWA NBI record, refreshed with each annual release.
ARBOR ST in Marion, Indiana sits above 8% of rated Indiana bridges on inventory load rating (22 t), while its 1989 build year is earlier than 31% of Marion's recorded-year cohort (958 bridges).
ARBOR ST in Marion, Indiana is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1989, it carries 1 rated component on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.
NBI record plate
Structure IN:4900512
LATE-CENTURY · MAT-OTHER · MULTI-SPAN · CULVERT-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR
- LATE-CENTURY 1980–1999
- MAT-OTHER Other
- MULTI-SPAN 2 spans
- CULVERT-LED Culvert-led
- ARTERIAL-ADT Arterial ADT
- STANDARD-LOAD Standard load
- CAT-FAIR Fair
Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.
Bridge Snapshot: ARBOR ST
The ARBOR ST bridge in Marion, Indiana carries ARBOR ST over HIGHLAND CREEK. It was built in 1989, making it 37 years old today. The structure is built primarily of aluminum/iron and spans 2 sections, stretching 13.1 meters (43 feet) end to end. Daily traffic averages 1,063 vehicles, placing it in the moderately-trafficked tier of Indiana bridges. It is owned and maintained by City/Municipal Highway Agency.
The latest FHWA inspection records show culvert at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.
How ARBOR ST compares
Age against the county: built in 1989, earlier than 298 of Marion's 958 bridges with a recorded construction year (31%), against a county median build year of 1970. This is one of the newer structures in its county.
Live comparison across Indiana bridges with a recorded inventory load rating (19,495 rated).
ARBOR ST vs every rated Indiana bridge
Inventory load rating (metric tons), FHWA NBI, this state
22 Top 92% higher than 8% of 19,495 bridges
rated Indiana bridges, bucketed by value
Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.
Source FHWA National Bridge Inventory · August 2026
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Marion inventory by recorded NBI category
Exclusive Good/Fair/Poor bands across all 958 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.
Structural Details
- Year Built
- 1989
- Material
- Aluminum/Iron
- Number of Spans
- 2
- Structure Length
- 13.1 m (43 ft)
- Deck Width
- 12.2 m (40 ft)
- Owner
- City/Municipal Highway Agency
- Avg Daily Traffic
- 1,063 vehicles/day
- Structure Number
- 4900512
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗How to read this record
This page shows what the last federal inspection recorded, not whether ARBOR ST is safe to cross today. Here is how to use it.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
- Compare ARBOR ST against other structures in Marion and across Indiana. Indiana bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for ARBOR ST?
ARBOR ST in Marion, Indiana on the FHWA's 0–9 scale.
How often is ARBOR ST inspected?
ARBOR ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,063 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. ARBOR ST is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for ARBOR ST?
ARBOR ST has an NBI inventory load rating of 21.8 metric tons.
Who is responsible for maintaining ARBOR ST?
ARBOR ST is owned and maintained by City/Municipal Highway Agency.
How old is ARBOR ST and does age affect safety?
ARBOR ST was built in 1989, making it 37 years old.
Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.
Share this inspection record
Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.
Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.