FHWA NBI 2024 Inspection record Public-domain dataset

UNIVERSITY PKWY NB

Carrying UNIVERSITY PKWY NB over LITTLE CREEK

00.45 N OF MARX RD, Vanderburgh, Indiana

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
50 t Inventory load rating Higher than 91% of rated Indiana bridges

UNIVERSITY PKWY NB in Vanderburgh, Indiana sits above 91% of rated Indiana bridges on inventory load rating (50 t), while its 2011 build year is earlier than 5% of Vanderburgh's recorded-year cohort (279 bridges).

UNIVERSITY PKWY NB in Vanderburgh, Indiana is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 2011, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IN:8200209

POST-2000 · STEEL · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · HEAVY-LOAD · CAT-GOOD

  • POST-2000 2000+
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: UNIVERSITY PKWY NB

The UNIVERSITY PKWY NB bridge in Vanderburgh, Indiana carries UNIVERSITY PKWY NB over LITTLE CREEK. It was built in 2011, making it 15 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 44.2 meters (145 feet) end to end. Daily traffic averages 3,207 vehicles, placing it in the moderately-trafficked tier of Indiana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range.

How UNIVERSITY PKWY NB compares

▲ 14.8
Load rating vs Indiana average (35.5 t; 19,495 rated)
279
Bridges in Vanderburgh · 12 in Poor condition

Age against the county: built in 2011, earlier than 14 of Vanderburgh's 279 bridges with a recorded construction year (5%), against a county median build year of 1987. This is one of the newer structures in its county.

UNIVERSITY PKWY NB 50.3 t
Indiana average (19,495 rated) 35.5 t

Live comparison across Indiana bridges with a recorded inventory load rating (19,495 rated).

UNIVERSITY PKWY NB vs every rated Indiana bridge

Inventory load rating (metric tons), FHWA NBI, this state

50 Top 9% higher than 91% of 19,495 bridges

rated Indiana bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
50.3 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Vanderburgh inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 279 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2011
Material
Steel Continuous
Number of Spans
3
Structure Length
44.2 m (145 ft)
Deck Width
13.7 m (45 ft)
Owner
County Highway Agency
Avg Daily Traffic
3,207 vehicles/day
Structure Number
8200209

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether UNIVERSITY PKWY NB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare UNIVERSITY PKWY NB against other structures in Vanderburgh and across Indiana. Indiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for UNIVERSITY PKWY NB?

UNIVERSITY PKWY NB in Vanderburgh, Indiana has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is UNIVERSITY PKWY NB inspected?

UNIVERSITY PKWY NB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,207 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. UNIVERSITY PKWY NB is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for UNIVERSITY PKWY NB?

UNIVERSITY PKWY NB has an NBI inventory load rating of 50.3 metric tons.

Who is responsible for maintaining UNIVERSITY PKWY NB?

UNIVERSITY PKWY NB is owned and maintained by County Highway Agency.

How old is UNIVERSITY PKWY NB and does age affect safety?

UNIVERSITY PKWY NB was built in 2011, making it 15 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.