FHWA NBI 2024 Inspection record Public-domain dataset

TEIGEN LOOP

Carrying TEIGEN LOOP over MCDONALD CREEK 032

S TEIGEN, Petroleum, Montana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
9 t Inventory load rating

Bridge Snapshot: TEIGEN LOOP

The TEIGEN LOOP bridge in Petroleum, Montana carries TEIGEN LOOP over MCDONALD CREEK 032. It was built in 2012, making it 14 years old today. The structure is built primarily of steel and spans 1 section, stretching 21.6 meters (71 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Montana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 9.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TEIGEN LOOP compares

▼ 21.6
Load rating vs Montana average (30.7 t)
Bottom 3%
Lower load rating than 97% of Montana bridges
26
Bridges in Petroleum · 4 in Poor condition
TEIGEN LOOP 9.1 t
Montana average 30.7 t

Live comparison across Montana.

Historical Sufficiency Rating

PlainBridge-computed
26.6 / 100 - historical 20–49.9 band
Structural adequacy /55
8.4
Serviceability /30
8.0
Essentiality /15
10.2
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
9.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2012
Material
Steel
Number of Spans
1
Structure Length
21.6 m (71 ft)
Deck Width
5.5 m (18 ft)
Owner
County Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
L35107000+04501

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether TEIGEN LOOP is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare TEIGEN LOOP against other structures in Petroleum and across Montana. Montana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TEIGEN LOOP?

TEIGEN LOOP in Petroleum, Montana has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is TEIGEN LOOP inspected?

TEIGEN LOOP's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TEIGEN LOOP is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TEIGEN LOOP?

TEIGEN LOOP has an NBI inventory load rating of 9.1 metric tons.

Who is responsible for maintaining TEIGEN LOOP?

TEIGEN LOOP is owned and maintained by County Highway Agency.

How old is TEIGEN LOOP and does age affect safety?

TEIGEN LOOP was built in 2012, making it 14 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.