FHWA NBI 2024 Inspection record Public-domain dataset

M 1880

Carrying M 1880 over MILLER CREEK

0.2 MI W OF JCT TH 53, St. Louis, Minnesota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
54 t Inventory load rating

Bridge Snapshot: M 1880

The M 1880 bridge in St. Louis, Minnesota carries M 1880 over MILLER CREEK. It was built in 1954, making it 72 years old today. The structure is built primarily of steel and spans 1 section, stretching 7.3 meters (24 feet) end to end. Daily traffic averages 175 vehicles, placing it in the lower-traffic tier of Minnesota bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 54.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How M 1880 compares

▲ 18.4
Load rating vs Minnesota average (35.7 t)
Top 2%
Higher load rating than 98% of Minnesota bridges
641
Bridges in St. Louis · 32 in Poor condition
M 1880 54.1 t
Minnesota average 35.7 t

Live comparison across Minnesota.

Historical Sufficiency Rating

PlainBridge-computed
76.1 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
22.8
Essentiality /15
13.4
Special reductions
−5.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
54.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1954
Material
Steel
Number of Spans
1
Structure Length
7.3 m (24 ft)
Deck Width
7.8 m (26 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
175 vehicles/day
Structure Number
L8478

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether M 1880 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare M 1880 against other structures in St. Louis and across Minnesota. Minnesota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for M 1880?

M 1880 in St. Louis, Minnesota has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is M 1880 inspected?

M 1880's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 175 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. M 1880 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for M 1880?

M 1880 has an NBI inventory load rating of 54.1 metric tons.

Who is responsible for maintaining M 1880?

M 1880 is owned and maintained by City/Municipal Highway Agency.

How old is M 1880 and does age affect safety?

M 1880 was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.