FHWA NBI 2024 Inspection record Public-domain dataset

LA0082

Carrying LA0082 over CREEK

1.97 MI N. OF LA 14, Vermilion, Louisiana

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
15 t Inventory load rating Lower than 94% of rated Louisiana bridges

LA0082 in Vermilion, Louisiana sits above 6% of rated Louisiana bridges on inventory load rating (15 t), while its 1960 build year is earlier than 78% of Vermilion's recorded-year cohort (261 bridges).

LA0082 in Vermilion, Louisiana is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1960, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure LA:035708576301971

INTERSTATE-ERA · TIMBER · MULTI-SPAN · SUB-LED · ARTERIAL-ADT · LIGHT-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • TIMBER Wood or timber
  • MULTI-SPAN 3 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: LA0082

The LA0082 bridge in Vermilion, Louisiana carries LA0082 over CREEK. It was built in 1960, making it 66 years old today. The structure is built primarily of wood or timber and spans 3 sections, stretching 17.7 meters (58 feet) end to end. Daily traffic averages 2,899 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How LA0082 compares

▼ 17.7
Load rating vs Louisiana average (32.2 t; 12,682 of 12,698 rated)
261
Bridges in Vermilion · 29 in Poor condition

Age against the county: built in 1960, earlier than 203 of Vermilion's 261 bridges with a recorded construction year (78%), against a county median build year of 1982. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

LA0082 14.5 t
Louisiana average (12,682 of 12,698 rated) 32.2 t

Live comparison across Louisiana bridges with a recorded inventory load rating (12,682 of 12,698 rated).

LA0082 vs every rated Louisiana bridge

Inventory load rating (metric tons), FHWA NBI, this state

15 Top 94% higher than 6% of 12,682 bridges

rated Louisiana bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
14.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Vermilion inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 261 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1960
Material
Wood or Timber
Number of Spans
3
Structure Length
17.7 m (58 ft)
Deck Width
8.2 m (27 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,899 vehicles/day
Structure Number
035708576301971

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

LA0082 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA0082 against other structures in Vermilion and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0082?

LA0082 in Vermilion, Louisiana has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LA0082 inspected?

LA0082's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,899 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0082 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0082?

LA0082 has an NBI inventory load rating of 14.5 metric tons.

Who is responsible for maintaining LA0082?

LA0082 is owned and maintained by State Highway Agency.

How old is LA0082 and does age affect safety?

LA0082 was built in 1960, making it 66 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.