FHWA NBI 2024 Inspection record Public-domain dataset

LA0082

Carrying LA0082 over LANGLINOIS DITCH

5.1 Miles North of LA 14, Vermilion, Louisiana

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
75 t Inventory load rating Higher than 97% of rated Louisiana bridges

LA0082 in Vermilion, Louisiana sits above 97% of rated Louisiana bridges on inventory load rating (75 t), while its 1963 build year is earlier than 74% of Vermilion's recorded-year cohort (261 bridges).

LA0082 in Vermilion, Louisiana is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1963, it carries 1 rated component on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure LA:035708576305771

INTERSTATE-ERA · STEEL · MULTI-SPAN · CULVERT-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • CULVERT-LED Culvert-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: LA0082

The LA0082 bridge in Vermilion, Louisiana carries LA0082 over LANGLINOIS DITCH. It was built in 1963, making it 63 years old today. The structure is built primarily of steel and spans 2 sections, stretching 8.5 meters (28 feet) end to end. Daily traffic averages 2,000 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show culvert at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How LA0082 compares

▲ 42.3
Load rating vs Louisiana average (32.2 t; 12,682 of 12,698 rated)
261
Bridges in Vermilion · 29 in Poor condition

Age against the county: built in 1963, earlier than 193 of Vermilion's 261 bridges with a recorded construction year (74%), against a county median build year of 1982. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

LA0082 74.5 t
Louisiana average (12,682 of 12,698 rated) 32.2 t

Live comparison across Louisiana bridges with a recorded inventory load rating (12,682 of 12,698 rated).

LA0082 vs every rated Louisiana bridge

Inventory load rating (metric tons), FHWA NBI, this state

75 Top 3% higher than 97% of 12,682 bridges

rated Louisiana bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Culvert
6/9
Fair (5–6)
Inventory Load Rating
74.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Vermilion inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 261 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1963
Material
Steel
Number of Spans
2
Structure Length
8.5 m (28 ft)
Deck Width
27.4 m (90 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,000 vehicles/day
Structure Number
035708576305771

How to read this record

This page shows what the last federal inspection recorded, not whether LA0082 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare LA0082 against other structures in Vermilion and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0082?

LA0082 in Vermilion, Louisiana on the FHWA's 0–9 scale.

How often is LA0082 inspected?

LA0082's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0082 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0082?

LA0082 has an NBI inventory load rating of 74.5 metric tons.

Who is responsible for maintaining LA0082?

LA0082 is owned and maintained by State Highway Agency.

How old is LA0082 and does age affect safety?

LA0082 was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.