FHWA NBI 2024 Inspection record Public-domain dataset

FDR 360

Carrying FDR 360 over BAYOU LIVROGNE

6.5 M. WSW.OF GORUM, Natchitoches, Louisiana

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
18 t Inventory load rating Lower than 89% of rated Louisiana bridges

FDR 360 in Natchitoches, Louisiana sits above 11% of rated Louisiana bridges on inventory load rating (18 t), while its 1978 build year is earlier than 61% of Natchitoches's recorded-year cohort (313 bridges).

FDR 360 in Natchitoches, Louisiana is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1978, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure LA:080603000002320

INTERSTATE-ERA · PRESTRESS · LONG-SPAN-RUN · SUPER-LED · TRACE-ADT · LIGHT-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 4 spans
  • SUPER-LED Superstructure-led
  • TRACE-ADT Trace ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FDR 360

The FDR 360 bridge in Natchitoches, Louisiana carries FDR 360 over BAYOU LIVROGNE. It was built in 1978, making it 48 years old today. The structure is built primarily of prestressed concrete and spans 4 sections, stretching 24.7 meters (81 feet) end to end. Daily traffic averages 30 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by U.S. Forest Service.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How FDR 360 compares

▼ 14.4
Load rating vs Louisiana average (32.2 t; 12,682 of 12,698 rated)
313
Bridges in Natchitoches · 48 in Poor condition

Age against the county: built in 1978, earlier than 192 of Natchitoches's 313 bridges with a recorded construction year (61%), against a county median build year of 1985. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

FDR 360 17.8 t
Louisiana average (12,682 of 12,698 rated) 32.2 t

Live comparison across Louisiana bridges with a recorded inventory load rating (12,682 of 12,698 rated).

FDR 360 vs every rated Louisiana bridge

Inventory load rating (metric tons), FHWA NBI, this state

18 Top 89% higher than 11% of 12,682 bridges

rated Louisiana bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
17.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Natchitoches inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 313 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1978
Material
Prestressed Concrete
Number of Spans
4
Structure Length
24.7 m (81 ft)
Deck Width
5.1 m (17 ft)
Owner
U.S. Forest Service
Avg Daily Traffic
30 vehicles/day
Structure Number
080603000002320

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether FDR 360 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FDR 360 against other structures in Natchitoches and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FDR 360?

FDR 360 in Natchitoches, Louisiana has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FDR 360 inspected?

FDR 360's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 30 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FDR 360 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FDR 360?

FDR 360 has an NBI inventory load rating of 17.8 metric tons.

Who is responsible for maintaining FDR 360?

FDR 360 is owned and maintained by U.S. Forest Service.

How old is FDR 360 and does age affect safety?

FDR 360 was built in 1978, making it 48 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.