FHWA NBI 2024 Inspection record Public-domain dataset

GENESEE AVE

Carrying GENESEE AVE over SAGINAW RIVER

IN CITY OF SAGINAW, Saginaw, Michigan

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
29 t Inventory load rating Lower than 84% of rated Michigan bridges

GENESEE AVE in Saginaw, Michigan sits above 16% of rated Michigan bridges on inventory load rating (29 t), while its 1973 build year is earlier than 57% of Saginaw's recorded-year cohort (315 bridges).

GENESEE AVE in Saginaw, Michigan is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1973, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 3. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure MI:000000000009446

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 6 spans
  • SUB-LED Substructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: GENESEE AVE

The GENESEE AVE bridge in Saginaw, Michigan carries GENESEE AVE over SAGINAW RIVER. It was built in 1973, making it 53 years old today. The structure is built primarily of steel continuous and spans 6 sections, stretching 144.8 meters (475 feet) end to end. Daily traffic averages 16,546 vehicles, placing it in the heavily-trafficked tier of Michigan bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 3/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How GENESEE AVE compares

▼ 12.0
Load rating vs Michigan average (41.2 t; 11,366 of 11,371 rated)
315
Bridges in Saginaw · 58 in Poor condition

Age against the county: built in 1973, earlier than 178 of Saginaw's 315 bridges with a recorded construction year (57%), against a county median build year of 1978. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

GENESEE AVE 29.2 t
Michigan average (11,366 of 11,371 rated) 41.2 t

Live comparison across Michigan bridges with a recorded inventory load rating (11,366 of 11,371 rated).

GENESEE AVE vs every rated Michigan bridge

Inventory load rating (metric tons), FHWA NBI, this state

29 Top 84% higher than 16% of 11,366 bridges

rated Michigan bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
29.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Saginaw inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 315 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1973
Material
Steel Continuous
Number of Spans
6
Structure Length
144.8 m (475 ft)
Deck Width
20.1 m (66 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
16,546 vehicles/day
Structure Number
000000000009446

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 3/9, the substructure (piers and abutments) is in poor shape, with advanced wear on file for this vintage.

How to read this record

GENESEE AVE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare GENESEE AVE against other structures in Saginaw and across Michigan. Michigan bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GENESEE AVE?

GENESEE AVE in Saginaw, Michigan has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is GENESEE AVE inspected?

GENESEE AVE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 16,546 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GENESEE AVE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GENESEE AVE?

GENESEE AVE has an NBI inventory load rating of 29.2 metric tons.

Who is responsible for maintaining GENESEE AVE?

GENESEE AVE is owned and maintained by City/Municipal Highway Agency.

How old is GENESEE AVE and does age affect safety?

GENESEE AVE was built in 1973, making it 53 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.