FHWA NBI 2024 Inspection record Public-domain dataset

SR2528

Carrying SR2528 over I85 & US601

0.4 MI. E. JCT. SR2540, Rowan, North Carolina

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
62 t Inventory load rating Higher than 84% of rated North Carolina bridges

SR2528 in Rowan, North Carolina sits above 84% of rated North Carolina bridges on inventory load rating (62 t), while its 2000 build year is earlier than 40% of Rowan's recorded-year cohort (245 bridges).

SR2528 in Rowan, North Carolina is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 2000, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NC:000000001590113

POST-2000 · STEEL · MULTI-SPAN · DECK-LED · HEAVY-ADT · HEAVY-LOAD · CAT-FAIR

  • POST-2000 2000+
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR2528

The SR2528 bridge in Rowan, North Carolina carries SR2528 over I85 & US601. It was built in 2000, making it 26 years old today. The structure is built primarily of steel continuous and spans 2 sections, stretching 79.2 meters (260 feet) end to end. Daily traffic averages 14,000 vehicles, placing it in the heavily-trafficked tier of North Carolina bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How SR2528 compares

▲ 17.0
Load rating vs North Carolina average (44.6 t; 19,160 of 19,210 rated)
245
Bridges in Rowan · 5 in Poor condition

Age against the county: built in 2000, earlier than 99 of Rowan's 245 bridges with a recorded construction year (40%), against a county median build year of 1996. This is one of the newer structures in its county.

SR2528 61.6 t
North Carolina average (19,160 of 19,210 rated) 44.6 t

Live comparison across North Carolina bridges with a recorded inventory load rating (19,160 of 19,210 rated).

SR2528 vs every rated North Carolina bridge

Inventory load rating (metric tons), FHWA NBI, this state

62 Top 16% higher than 84% of 19,160 bridges

rated North Carolina bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
61.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Rowan inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 245 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2000
Material
Steel Continuous
Number of Spans
2
Structure Length
79.2 m (260 ft)
Deck Width
22.9 m (75 ft)
Owner
State Highway Agency
Avg Daily Traffic
14,000 vehicles/day
Structure Number
000000001590113

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SR2528 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR2528 against other structures in Rowan and across North Carolina. North Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR2528?

SR2528 in Rowan, North Carolina has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR2528 inspected?

SR2528's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 14,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR2528 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR2528?

SR2528 has an NBI inventory load rating of 61.6 metric tons.

Who is responsible for maintaining SR2528?

SR2528 is owned and maintained by State Highway Agency.

How old is SR2528 and does age affect safety?

SR2528 was built in 2000, making it 26 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.