FHWA NBI 2024 Inspection record Public-domain dataset

SR1224

Carrying SR1224 over E.PRONG LITTLE YADKIN R.

150 FT. S. JCT. SR1163, Stokes, North Carolina

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
44 t Inventory load rating Higher than 57% of rated North Carolina bridges

SR1224 in Stokes, North Carolina sits above 57% of rated North Carolina bridges on inventory load rating (44 t), while its 1950 build year is earlier than 94% of Stokes's recorded-year cohort (150 bridges).

SR1224 in Stokes, North Carolina is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1950, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NC:000000001690212

INTERSTATE-ERA · STEEL · SINGLE-SPAN · TIED-CTRL · LOCAL-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR1224

The SR1224 bridge in Stokes, North Carolina carries SR1224 over E.PRONG LITTLE YADKIN R.. It was built in 1950, making it 76 years old today. It was last reconstructed in 1982, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 15.5 meters (51 feet) end to end. Daily traffic averages 140 vehicles, placing it in the lower-traffic tier of North Carolina bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How SR1224 compares

▼ 0.2
Load rating vs North Carolina average (44.6 t; 19,160 of 19,210 rated)
150
Bridges in Stokes · 15 in Poor condition

Age against the county: built in 1950, earlier than 141 of Stokes's 150 bridges with a recorded construction year (94%), against a county median build year of 1991. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SR1224 44.4 t
North Carolina average (19,160 of 19,210 rated) 44.6 t

Live comparison across North Carolina bridges with a recorded inventory load rating (19,160 of 19,210 rated).

SR1224 vs every rated North Carolina bridge

Inventory load rating (metric tons), FHWA NBI, this state

44 Top 43% higher than 57% of 19,160 bridges

rated North Carolina bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
44.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Stokes inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 150 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1950
Last Reconstructed
1982
Material
Steel
Number of Spans
1
Structure Length
15.5 m (51 ft)
Deck Width
6.1 m (20 ft)
Owner
State Highway Agency
Avg Daily Traffic
140 vehicles/day
Structure Number
000000001690212

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether SR1224 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR1224 against other structures in Stokes and across North Carolina. North Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR1224?

SR1224 in Stokes, North Carolina has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR1224 inspected?

SR1224's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 140 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR1224 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR1224?

SR1224 has an NBI inventory load rating of 44.4 metric tons.

Who is responsible for maintaining SR1224?

SR1224 is owned and maintained by State Highway Agency.

How old is SR1224 and does age affect safety?

SR1224 was built in 1950, making it 76 years old and last reconstructed in 1982.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.