Fair
25 t Inventory load rating Lower than 53% of rated Nebraska bridges

VAN DORN / FAS3320 in Lancaster, Nebraska sits above 47% of rated Nebraska bridges on inventory load rating (25 t), while its 1983 build year is earlier than 56% of Lancaster's recorded-year cohort (661 bridges).

VAN DORN / FAS3320 in Lancaster, Nebraska is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1983, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NE:C005503805

LATE-CENTURY · STEEL · MULTI-SPAN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: VAN DORN / FAS3320

The VAN DORN / FAS3320 bridge in Lancaster, Nebraska carries VAN DORN / FAS3320 over BNSFRR 070-130-M (M-10). It was built in 1983, making it 43 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 50.3 meters (165 feet) end to end. Daily traffic averages 2,442 vehicles, placing it in the moderately-trafficked tier of Nebraska bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How VAN DORN / FAS3320 compares

▼ 2.4
Load rating vs Nebraska average (27.4 t; 15,392 of 15,398 rated)
661
Bridges in Lancaster · 32 in Poor condition

Age against the county: built in 1983, earlier than 373 of Lancaster's 661 bridges with a recorded construction year (56%), against a county median build year of 1988. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

VAN DORN / FAS3320 25.0 t
Nebraska average (15,392 of 15,398 rated) 27.4 t

Live comparison across Nebraska bridges with a recorded inventory load rating (15,392 of 15,398 rated).

VAN DORN / FAS3320 vs every rated Nebraska bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 53% higher than 47% of 15,392 bridges

rated Nebraska bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
25.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lancaster inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 661 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1983
Material
Steel Continuous
Number of Spans
3
Structure Length
50.3 m (165 ft)
Deck Width
9.2 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
2,442 vehicles/day
Structure Number
C005503805

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether VAN DORN / FAS3320 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare VAN DORN / FAS3320 against other structures in Lancaster and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for VAN DORN / FAS3320?

VAN DORN / FAS3320 in Lancaster, Nebraska has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is VAN DORN / FAS3320 inspected?

VAN DORN / FAS3320's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,442 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. VAN DORN / FAS3320 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for VAN DORN / FAS3320?

VAN DORN / FAS3320 has an NBI inventory load rating of 25.0 metric tons.

Who is responsible for maintaining VAN DORN / FAS3320?

VAN DORN / FAS3320 is owned and maintained by County Highway Agency.

How old is VAN DORN / FAS3320 and does age affect safety?

VAN DORN / FAS3320 was built in 1983, making it 43 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.