FHWA NBI 2024 Inspection record Public-domain dataset

72ND ST/FAU 5037

Carrying 72ND ST/FAU 5037 over UPRR 816-828-J

OMAHA 72ND @ F, Douglas, Nebraska

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
32 t Inventory load rating Higher than 59% of rated Nebraska bridges

72ND ST/FAU 5037 in Douglas, Nebraska sits above 59% of rated Nebraska bridges on inventory load rating (32 t), while its 1966 build year is earlier than 81% of Douglas's recorded-year cohort (509 bridges).

72ND ST/FAU 5037 in Douglas, Nebraska is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1966, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NE:U182504710

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 5 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 72ND ST/FAU 5037

The 72ND ST/FAU 5037 bridge in Douglas, Nebraska carries 72ND ST/FAU 5037 over UPRR 816-828-J. It was built in 1966, making it 60 years old today. It was last reconstructed in 1979, extending its service life. The structure is built primarily of steel continuous and spans 5 sections, stretching 77.1 meters (253 feet) end to end. Daily traffic averages 56,260 vehicles, placing it in the heavily-trafficked tier of Nebraska bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How 72ND ST/FAU 5037 compares

▲ 4.6
Load rating vs Nebraska average (27.4 t; 15,392 of 15,398 rated)
509
Bridges in Douglas · 15 in Poor condition

Age against the county: built in 1966, earlier than 412 of Douglas's 509 bridges with a recorded construction year (81%), against a county median build year of 1988. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

72ND ST/FAU 5037 32.0 t
Nebraska average (15,392 of 15,398 rated) 27.4 t

Live comparison across Nebraska bridges with a recorded inventory load rating (15,392 of 15,398 rated).

72ND ST/FAU 5037 vs every rated Nebraska bridge

Inventory load rating (metric tons), FHWA NBI, this state

32 Top 41% higher than 59% of 15,392 bridges

rated Nebraska bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
32.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Douglas inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 509 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1966
Last Reconstructed
1979
Material
Steel Continuous
Number of Spans
5
Structure Length
77.1 m (253 ft)
Deck Width
23.0 m (75 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
56,260 vehicles/day
Structure Number
U182504710

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

72ND ST/FAU 5037 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 72ND ST/FAU 5037 against other structures in Douglas and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 72ND ST/FAU 5037?

72ND ST/FAU 5037 in Douglas, Nebraska has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is 72ND ST/FAU 5037 inspected?

72ND ST/FAU 5037's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 56,260 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 72ND ST/FAU 5037 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 72ND ST/FAU 5037?

72ND ST/FAU 5037 has an NBI inventory load rating of 32.0 metric tons.

Who is responsible for maintaining 72ND ST/FAU 5037?

72ND ST/FAU 5037 is owned and maintained by City/Municipal Highway Agency.

How old is 72ND ST/FAU 5037 and does age affect safety?

72ND ST/FAU 5037 was built in 1966, making it 60 years old and last reconstructed in 1979.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.