FHWA NBI 2024 Inspection record Public-domain dataset

PASSAIC AV

Carrying PASSAIC AV over THIRD RIVER

0.97 miles north of CR648, Essex, New Jersey

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating Lower than 88% of rated New Jersey bridges

PASSAIC AV in Essex, New Jersey sits above 12% of rated New Jersey bridges on inventory load rating (25 t), while its 1963 build year is earlier than 59% of Essex's recorded-year cohort (505 bridges).

PASSAIC AV in Essex, New Jersey is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1963, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NJ:0705465

INTERSTATE-ERA · PRESTRESS · SINGLE-SPAN · TIED-CTRL · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: PASSAIC AV

The PASSAIC AV bridge in Essex, New Jersey carries PASSAIC AV over THIRD RIVER. It was built in 1963, making it 63 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 17.7 meters (58 feet) end to end. Daily traffic averages 11,837 vehicles, placing it in the heavily-trafficked tier of New Jersey bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How PASSAIC AV compares

▼ 19.0
Load rating vs New Jersey average (43.5 t; 6,826 of 6,827 rated)
505
Bridges in Essex · 14 in Poor condition

Age against the county: built in 1963, earlier than 298 of Essex's 505 bridges with a recorded construction year (59%), against a county median build year of 1967. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

PASSAIC AV 24.5 t
New Jersey average (6,826 of 6,827 rated) 43.5 t

Live comparison across New Jersey bridges with a recorded inventory load rating (6,826 of 6,827 rated).

PASSAIC AV vs every rated New Jersey bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 88% higher than 12% of 6,826 bridges

rated New Jersey bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
24.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Essex inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 505 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1963
Material
Prestressed Concrete
Number of Spans
1
Structure Length
17.7 m (58 ft)
Deck Width
14.8 m (49 ft)
Owner
County Highway Agency
Avg Daily Traffic
11,837 vehicles/day
Structure Number
0705465

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether PASSAIC AV is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PASSAIC AV against other structures in Essex and across New Jersey. New Jersey bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PASSAIC AV?

PASSAIC AV in Essex, New Jersey has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is PASSAIC AV inspected?

PASSAIC AV's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,837 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PASSAIC AV is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PASSAIC AV?

PASSAIC AV has an NBI inventory load rating of 24.5 metric tons.

Who is responsible for maintaining PASSAIC AV?

PASSAIC AV is owned and maintained by County Highway Agency.

How old is PASSAIC AV and does age affect safety?

PASSAIC AV was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.