FHWA NBI 2024 Inspection record Public-domain dataset

IN-2412

Carrying IN-2412 over LITTLE CREEK

9.7 MI N COLFAX/MORA CL, Colfax, New Mexico

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
35 t Inventory load rating Higher than 81% of rated New Mexico bridges

IN-2412 in Colfax, New Mexico sits above 81% of rated New Mexico bridges on inventory load rating (35 t), while its 1973 build year is earlier than 25% of Colfax's recorded-year cohort (140 bridges).

IN-2412 in Colfax, New Mexico is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1973, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NM:000000000007291

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: IN-2412

The IN-2412 bridge in Colfax, New Mexico carries IN-2412 over LITTLE CREEK. It was built in 1973, making it 53 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 45.7 meters (150 feet) end to end. Daily traffic averages 67 vehicles, placing it in the lower-traffic tier of New Mexico bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How IN-2412 compares

▲ 1.9
Load rating vs New Mexico average (32.7 t; 4,030 of 4,035 rated)
140
Bridges in Colfax · 7 in Poor condition

Age against the county: built in 1973, earlier than 35 of Colfax's 140 bridges with a recorded construction year (25%), against a county median build year of 1969. This is one of the newer structures in its county.

IN-2412 34.6 t
New Mexico average (4,030 of 4,035 rated) 32.7 t

Live comparison across New Mexico bridges with a recorded inventory load rating (4,030 of 4,035 rated).

IN-2412 vs every rated New Mexico bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 19% higher than 81% of 4,030 bridges

rated New Mexico bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
34.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Colfax inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 140 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1973
Material
Prestressed Concrete
Number of Spans
3
Structure Length
45.7 m (150 ft)
Deck Width
8.2 m (27 ft)
Owner
State Highway Agency
Avg Daily Traffic
67 vehicles/day
Structure Number
000000000007291

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

IN-2412 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IN-2412 against other structures in Colfax and across New Mexico. New Mexico bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IN-2412?

IN-2412 in Colfax, New Mexico has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is IN-2412 inspected?

IN-2412's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 67 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IN-2412 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IN-2412?

IN-2412 has an NBI inventory load rating of 34.6 metric tons.

Who is responsible for maintaining IN-2412?

IN-2412 is owned and maintained by State Highway Agency.

How old is IN-2412 and does age affect safety?

IN-2412 was built in 1973, making it 53 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.