FHWA NBI 2024 Inspection record Public-domain dataset

RTE I590

Carrying RTE I590 over 31 31 43033019 WB RTE 3

1.0MI SE JCT 31+47 NB ROL, Monroe, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
23 t Inventory load rating Lower than 90% of rated New York bridges

RTE I590 in Monroe, New York sits above 10% of rated New York bridges on inventory load rating (23 t), while its 1966 build year is earlier than 66% of Monroe's recorded-year cohort (615 bridges).

RTE I590 in Monroe, New York is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1966, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000001021662

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • SUB-LED Substructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: RTE I590

The RTE I590 bridge in Monroe, New York carries RTE I590 over 31 31 43033019 WB RTE 3. It was built in 1966, making it 60 years old today. It was last reconstructed in 1987, extending its service life. The structure is built primarily of steel and spans 4 sections, stretching 81.4 meters (267 feet) end to end. Daily traffic averages 37,014 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How RTE I590 compares

▼ 19.0
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
615
Bridges in Monroe · 67 in Poor condition

Age against the county: built in 1966, earlier than 406 of Monroe's 615 bridges with a recorded construction year (66%), against a county median build year of 1976. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

RTE I590 22.7 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

RTE I590 vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

23 Top 90% higher than 10% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
22.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Monroe inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 615 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1966
Last Reconstructed
1987
Material
Steel
Number of Spans
4
Structure Length
81.4 m (267 ft)
Deck Width
16.5 m (54 ft)
Owner
State Highway Agency
Avg Daily Traffic
37,014 vehicles/day
Structure Number
000000001021662

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.

How to read this record

RTE I590 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE I590 against other structures in Monroe and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE I590?

RTE I590 in Monroe, New York has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is RTE I590 inspected?

RTE I590's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 37,014 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE I590 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE I590?

RTE I590 has an NBI inventory load rating of 22.7 metric tons.

Who is responsible for maintaining RTE I590?

RTE I590 is owned and maintained by State Highway Agency.

How old is RTE I590 and does age affect safety?

RTE I590 was built in 1966, making it 60 years old and last reconstructed in 1987.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.