FHWA NBI 2024 Inspection record Public-domain dataset

CR 32

Carrying CR 32 over 87I 87I15091293 RTE I87

JCT I87 & GANSEVOORT RD, Saratoga, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
35 t Inventory load rating Lower than 65% of rated New York bridges

CR 32 in Saratoga, New York sits above 35% of rated New York bridges on inventory load rating (35 t), while its 1962 build year is earlier than 54% of Saratoga's recorded-year cohort (228 bridges).

CR 32 in Saratoga, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1962, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000001033400

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 6 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: CR 32

The CR 32 bridge in Saratoga, New York carries CR 32 over 87I 87I15091293 RTE I87. It was built in 1962, making it 64 years old today. It was last reconstructed in 2009, extending its service life. The structure is built primarily of steel and spans 6 sections, stretching 99.4 meters (326 feet) end to end. Daily traffic averages 1,011 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How CR 32 compares

▼ 7.2
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
228
Bridges in Saratoga · 17 in Poor condition

Age against the county: built in 1962, earlier than 124 of Saratoga's 228 bridges with a recorded construction year (54%), against a county median build year of 1969. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

CR 32 34.5 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

CR 32 vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 65% higher than 35% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
34.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Saratoga inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 228 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1962
Last Reconstructed
2009
Material
Steel
Number of Spans
6
Structure Length
99.4 m (326 ft)
Deck Width
10.8 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,011 vehicles/day
Structure Number
000000001033400

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether CR 32 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare CR 32 against other structures in Saratoga and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CR 32?

CR 32 in Saratoga, New York has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is CR 32 inspected?

CR 32's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,011 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CR 32 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CR 32?

CR 32 has an NBI inventory load rating of 34.5 metric tons.

Who is responsible for maintaining CR 32?

CR 32 is owned and maintained by State Highway Agency.

How old is CR 32 and does age affect safety?

CR 32 was built in 1962, making it 64 years old and last reconstructed in 2009.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.