FHWA NBI 2024 Inspection record Public-domain dataset

CR 9 ANGOLA BRANT

Carrying CR 9 ANGOLA BRANT over 90IX RTE I90

1.8 MI SE OF ANGOLA, Erie, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
35 t Inventory load rating Lower than 64% of rated New York bridges

CR 9 ANGOLA BRANT in Erie, New York sits above 36% of rated New York bridges on inventory load rating (35 t), while its 1957 build year is earlier than 73% of Erie's recorded-year cohort (906 bridges).

CR 9 ANGOLA BRANT in Erie, New York is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1957, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000001045720

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 5 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: CR 9 ANGOLA BRANT

The CR 9 ANGOLA BRANT bridge in Erie, New York carries CR 9 ANGOLA BRANT over 90IX RTE I90. It was built in 1957, making it 69 years old today. The structure is built primarily of steel and spans 5 sections, stretching 110.3 meters (362 feet) end to end. Daily traffic averages 2,233 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by State Toll Authority.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How CR 9 ANGOLA BRANT compares

▼ 7.0
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
906
Bridges in Erie · 79 in Poor condition

Age against the county: built in 1957, earlier than 661 of Erie's 906 bridges with a recorded construction year (73%), against a county median build year of 1972. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

CR 9 ANGOLA BRANT 34.7 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

CR 9 ANGOLA BRANT vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 64% higher than 36% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
34.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Erie inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 906 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1957
Material
Steel
Number of Spans
5
Structure Length
110.3 m (362 ft)
Deck Width
11.9 m (39 ft)
Owner
State Toll Authority
Avg Daily Traffic
2,233 vehicles/day
Structure Number
000000001045720

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

CR 9 ANGOLA BRANT is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CR 9 ANGOLA BRANT against other structures in Erie and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CR 9 ANGOLA BRANT?

CR 9 ANGOLA BRANT in Erie, New York has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is CR 9 ANGOLA BRANT inspected?

CR 9 ANGOLA BRANT's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,233 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CR 9 ANGOLA BRANT is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CR 9 ANGOLA BRANT?

CR 9 ANGOLA BRANT has an NBI inventory load rating of 34.7 metric tons.

Who is responsible for maintaining CR 9 ANGOLA BRANT?

CR 9 ANGOLA BRANT is owned and maintained by State Toll Authority.

How old is CR 9 ANGOLA BRANT and does age affect safety?

CR 9 ANGOLA BRANT was built in 1957, making it 69 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.