RTE 907F
Carrying RTE 907F over RTE 908A RTE 908A
.4 MI SW I95+HTCHSN R PKY, Bronx, New York
Inventory: FHWA NBI 2024 · last ETL August 2026
FHWA NBI record, refreshed with each annual release.
RTE 907F in Bronx, New York sits above 25% of rated New York bridges on inventory load rating (33 t), while its 1942 build year is earlier than 60% of Bronx's recorded-year cohort (311 bridges).
RTE 907F in Bronx, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1942, it carries 2 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.
NBI record plate
Structure NY:000000002075849
PRE-1950 · CONCRETE · MULTI-SPAN · TIED-CTRL · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR
- PRE-1950 Pre-1950
- CONCRETE Concrete
- MULTI-SPAN 2 spans
- TIED-CTRL Tied control
- HEAVY-ADT Heavy ADT
- STANDARD-LOAD Standard load
- CAT-FAIR Fair
Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.
Bridge Snapshot: RTE 907F
The RTE 907F bridge in Bronx, New York carries RTE 907F over RTE 908A RTE 908A. It was built in 1942, making it 84 years old today. The structure is built primarily of concrete and spans 2 sections, stretching 37.5 meters (123 feet) end to end. Daily traffic averages 40,586 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by City/Municipal Highway Agency.
The latest FHWA inspection records show superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range.
How RTE 907F compares
Age against the county: built in 1942, earlier than 187 of Bronx's 311 bridges with a recorded construction year (60%), against a county median build year of 1951. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.
Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).
RTE 907F vs every rated New York bridge
Inventory load rating (metric tons), FHWA NBI, this state
33 Top 75% higher than 25% of 17,641 bridges
rated New York bridges, bucketed by value
Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.
Source FHWA National Bridge Inventory · August 2026
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.
Bronx inventory by recorded NBI category
Exclusive Good/Fair/Poor bands across all 311 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.
Structural Details
- Year Built
- 1942
- Material
- Concrete
- Number of Spans
- 2
- Structure Length
- 37.5 m (123 ft)
- Deck Width
- 44.7 m (147 ft)
- Owner
- City/Municipal Highway Agency
- Avg Daily Traffic
- 40,586 vehicles/day
- Structure Number
- 000000002075849
Condition Analysis
- • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
- • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗How to read this record
This page shows what the last federal inspection recorded, not whether RTE 907F is safe to cross today. Here is how to use it.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
- Compare RTE 907F against other structures in Bronx and across New York. New York bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for RTE 907F?
RTE 907F in Bronx, New York, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.
How often is RTE 907F inspected?
RTE 907F's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 40,586 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. RTE 907F is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for RTE 907F?
RTE 907F has an NBI inventory load rating of 32.7 metric tons.
Who is responsible for maintaining RTE 907F?
RTE 907F is owned and maintained by City/Municipal Highway Agency.
How old is RTE 907F and does age affect safety?
RTE 907F was built in 1942, making it 84 years old.
Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.
Share this inspection record
Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.
Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.