FHWA NBI 2024 Inspection record Public-domain dataset

MANHATTAN COL PKY

Carrying MANHATTAN COL PKY over RTE 907V RTE 907V SRD

1.2 MI NE H.HUDSON BR+9A, Bronx, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
24 t Inventory load rating Lower than 88% of rated New York bridges

MANHATTAN COL PKY in Bronx, New York sits above 12% of rated New York bridges on inventory load rating (24 t), while its 1938 build year is earlier than 63% of Bronx's recorded-year cohort (311 bridges).

MANHATTAN COL PKY in Bronx, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1938, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000002229480

PRE-1950 · CONCRETE · MULTI-SPAN · DECK-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • MULTI-SPAN 3 spans
  • DECK-LED Deck-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: MANHATTAN COL PKY

The MANHATTAN COL PKY bridge in Bronx, New York carries MANHATTAN COL PKY over RTE 907V RTE 907V SRD. It was built in 1938, making it 88 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 39.9 meters (131 feet) end to end. Daily traffic averages 1,511 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How MANHATTAN COL PKY compares

▼ 17.8
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
311
Bridges in Bronx · 26 in Poor condition

Age against the county: built in 1938, earlier than 197 of Bronx's 311 bridges with a recorded construction year (63%), against a county median build year of 1951. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

MANHATTAN COL PKY 23.9 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

MANHATTAN COL PKY vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

24 Top 88% higher than 12% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
23.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Bronx inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 311 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1938
Material
Concrete Continuous
Number of Spans
3
Structure Length
39.9 m (131 ft)
Deck Width
13.1 m (43 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
1,511 vehicles/day
Structure Number
000000002229480

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether MANHATTAN COL PKY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare MANHATTAN COL PKY against other structures in Bronx and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MANHATTAN COL PKY?

MANHATTAN COL PKY in Bronx, New York has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is MANHATTAN COL PKY inspected?

MANHATTAN COL PKY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,511 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MANHATTAN COL PKY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MANHATTAN COL PKY?

MANHATTAN COL PKY has an NBI inventory load rating of 23.9 metric tons.

Who is responsible for maintaining MANHATTAN COL PKY?

MANHATTAN COL PKY is owned and maintained by City/Municipal Highway Agency.

How old is MANHATTAN COL PKY and does age affect safety?

MANHATTAN COL PKY was built in 1938, making it 88 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.