FHWA NBI 2024 Inspection record Public-domain dataset

FOSTER AVENUE

Carrying FOSTER AVENUE over NYCTA Brighton Line

IN KENSINGTON, Kings, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
16 t Inventory load rating Lower than 96% of rated New York bridges

FOSTER AVENUE in Kings, New York sits above 4% of rated New York bridges on inventory load rating (16 t), while its 1907 build year is earlier than 91% of Kings's recorded-year cohort (242 bridges).

FOSTER AVENUE in Kings, New York is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1907, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000002243150

PRE-1950 · STEEL · SINGLE-SPAN · SUPER-LED · HEAVY-ADT · LIGHT-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • SUPER-LED Superstructure-led
  • HEAVY-ADT Heavy ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Structural health score

A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.

F
Overall Score
17/100
FOSTER AVENUE
Deck Condition F
6/9
NBI deck condition rating (0=failed, 9=excellent)
Superstructure Condition F
4/9
NBI superstructure condition rating (0=failed, 9=excellent)
Substructure Condition F
6/9
NBI substructure condition rating (0=failed, 9=excellent)
Load Rating F
16 t
NBI inventory load rating vs the national corpus

Bridge Snapshot: FOSTER AVENUE

The FOSTER AVENUE bridge in Kings, New York carries FOSTER AVENUE over NYCTA Brighton Line. It was built in 1907, making it 119 years old today. The structure is built primarily of steel and spans 1 section, stretching 21.3 meters (70 feet) end to end. Daily traffic averages 11,992 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by Other Local Agencies.

The latest FHWA inspection places the weakest component in poor condition (see the full component ratings below). A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How FOSTER AVENUE compares

▼ 26.0
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
242
Bridges in Kings · 27 in Poor condition

Age against the county: built in 1907, earlier than 220 of Kings's 242 bridges with a recorded construction year (91%), against a county median build year of 1955. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

FOSTER AVENUE 15.7 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

FOSTER AVENUE vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

16 Top 96% higher than 4% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
15.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Kings inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 242 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1907
Material
Steel
Number of Spans
1
Structure Length
21.3 m (70 ft)
Deck Width
19.8 m (65 ft)
Owner
Other Local Agencies
Avg Daily Traffic
11,992 vehicles/day
Structure Number
000000002243150

Condition Analysis

  • • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • • The superstructure (beams and supports above the deck) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

FOSTER AVENUE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FOSTER AVENUE against other structures in Kings and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FOSTER AVENUE?

FOSTER AVENUE in Kings, New York has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FOSTER AVENUE inspected?

FOSTER AVENUE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,992 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FOSTER AVENUE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FOSTER AVENUE?

FOSTER AVENUE has an NBI inventory load rating of 15.7 metric tons.

Who is responsible for maintaining FOSTER AVENUE?

FOSTER AVENUE is owned and maintained by Other Local Agencies.

How old is FOSTER AVENUE and does age affect safety?

FOSTER AVENUE was built in 1907, making it 119 years old.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.