FHWA NBI 2024 Inspection record Public-domain dataset

E SENECA STREET

Carrying E SENECA STREET over CSX TRANSPRTATION

IN OSWEGO, Oswego, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
40 t Inventory load rating Lower than 53% of rated New York bridges

E SENECA STREET in Oswego, New York sits above 47% of rated New York bridges on inventory load rating (40 t), while its 1939 build year is earlier than 88% of Oswego's recorded-year cohort (233 bridges).

E SENECA STREET in Oswego, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1939, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000002256290

PRE-1950 · PRESTRESS · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 4 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: E SENECA STREET

The E SENECA STREET bridge in Oswego, New York carries E SENECA STREET over CSX TRANSPRTATION. It was built in 1939, making it 87 years old today. It was last reconstructed in 1980, extending its service life. The structure is built primarily of prestressed concrete continuous and spans 4 sections, stretching 86.3 meters (283 feet) end to end. Daily traffic averages 2,536 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How E SENECA STREET compares

▼ 1.5
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
233
Bridges in Oswego · 24 in Poor condition

Age against the county: built in 1939, earlier than 204 of Oswego's 233 bridges with a recorded construction year (88%), against a county median build year of 1977. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

E SENECA STREET 40.2 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

E SENECA STREET vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

40 Top 53% higher than 47% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
40.2 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Oswego inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 233 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1939
Last Reconstructed
1980
Material
Prestressed Concrete Continuous
Number of Spans
4
Structure Length
86.3 m (283 ft)
Deck Width
12.8 m (42 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
2,536 vehicles/day
Structure Number
000000002256290

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether E SENECA STREET is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare E SENECA STREET against other structures in Oswego and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E SENECA STREET?

E SENECA STREET in Oswego, New York has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is E SENECA STREET inspected?

E SENECA STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,536 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E SENECA STREET is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E SENECA STREET?

E SENECA STREET has an NBI inventory load rating of 40.2 metric tons.

Who is responsible for maintaining E SENECA STREET?

E SENECA STREET is owned and maintained by City/Municipal Highway Agency.

How old is E SENECA STREET and does age affect safety?

E SENECA STREET was built in 1939, making it 87 years old and last reconstructed in 1980.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.