FHWA NBI 2024 Inspection record Public-domain dataset

STANTON CORNRS RD

Carrying STANTON CORNRS RD over MIDDL MONGAUP RVR

2.2 MILES SW OF FERNDALE, Sullivan, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
51 t Inventory load rating Higher than 75% of rated New York bridges

STANTON CORNRS RD in Sullivan, New York sits above 75% of rated New York bridges on inventory load rating (51 t), while its 1935 build year is earlier than 88% of Sullivan's recorded-year cohort (365 bridges).

STANTON CORNRS RD in Sullivan, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1935, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000003356810

PRE-1950 · PRESTRESS · SINGLE-SPAN · DECK-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • DECK-LED Deck-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: STANTON CORNRS RD

The STANTON CORNRS RD bridge in Sullivan, New York carries STANTON CORNRS RD over MIDDL MONGAUP RVR. It was built in 1935, making it 91 years old today. It was last reconstructed in 1999, extending its service life. The structure is built primarily of prestressed concrete and spans 1 section, stretching 12.8 meters (42 feet) end to end. Daily traffic averages 1,118 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How STANTON CORNRS RD compares

▲ 9.1
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
365
Bridges in Sullivan · 28 in Poor condition

Age against the county: built in 1935, earlier than 322 of Sullivan's 365 bridges with a recorded construction year (88%), against a county median build year of 1970. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

STANTON CORNRS RD 50.8 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

STANTON CORNRS RD vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

51 Top 25% higher than 75% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
50.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Sullivan inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 365 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1935
Last Reconstructed
1999
Material
Prestressed Concrete
Number of Spans
1
Structure Length
12.8 m (42 ft)
Deck Width
7.4 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
1,118 vehicles/day
Structure Number
000000003356810

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in good condition (8/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (8/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether STANTON CORNRS RD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare STANTON CORNRS RD against other structures in Sullivan and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for STANTON CORNRS RD?

STANTON CORNRS RD in Sullivan, New York has a deck rating of 6/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is STANTON CORNRS RD inspected?

STANTON CORNRS RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,118 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. STANTON CORNRS RD is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for STANTON CORNRS RD?

STANTON CORNRS RD has an NBI inventory load rating of 50.8 metric tons.

Who is responsible for maintaining STANTON CORNRS RD?

STANTON CORNRS RD is owned and maintained by County Highway Agency.

How old is STANTON CORNRS RD and does age affect safety?

STANTON CORNRS RD was built in 1935, making it 91 years old and last reconstructed in 1999.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.