FHWA NBI 2024 Inspection record Public-domain dataset

SR 0006 TR 6

Carrying SR 0006 TR 6 over DELAWARE RIVER

PORT JERVIS PIKE ST, Orange, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
33 t Inventory load rating Lower than 75% of rated New York bridges

SR 0006 TR 6 in Orange, New York sits above 25% of rated New York bridges on inventory load rating (33 t), while its 1939 build year is earlier than 87% of Orange's recorded-year cohort (472 bridges).

SR 0006 TR 6 in Orange, New York is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1939, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000005223060

PRE-1950 · STEEL · MULTI-SPAN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 0006 TR 6

The SR 0006 TR 6 bridge in Orange, New York carries SR 0006 TR 6 over DELAWARE RIVER. It was built in 1939, making it 87 years old today. The structure is built primarily of steel and spans 2 sections, stretching 200.9 meters (659 feet) end to end. Daily traffic averages 16,932 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How SR 0006 TR 6 compares

▼ 9.0
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
472
Bridges in Orange · 72 in Poor condition

Age against the county: built in 1939, earlier than 412 of Orange's 472 bridges with a recorded construction year (87%), against a county median build year of 1968. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SR 0006 TR 6 32.7 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

SR 0006 TR 6 vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

33 Top 75% higher than 25% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Orange inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 472 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1939
Material
Steel
Number of Spans
2
Structure Length
200.9 m (659 ft)
Deck Width
14.0 m (46 ft)
Owner
State Highway Agency
Avg Daily Traffic
16,932 vehicles/day
Structure Number
000000005223060

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

SR 0006 TR 6 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 0006 TR 6 against other structures in Orange and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 0006 TR 6?

SR 0006 TR 6 in Orange, New York has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SR 0006 TR 6 inspected?

SR 0006 TR 6's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 16,932 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 0006 TR 6 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 0006 TR 6?

SR 0006 TR 6 has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining SR 0006 TR 6?

SR 0006 TR 6 is owned and maintained by State Highway Agency.

How old is SR 0006 TR 6 and does age affect safety?

SR 0006 TR 6 was built in 1939, making it 87 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.