FHWA NBI 2024 Inspection record Public-domain dataset

RTE I90

Carrying RTE I90 over 87IX RTE I87

2.7 MILES NW OF RAVENA, Albany, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
33 t Inventory load rating Lower than 75% of rated New York bridges

RTE I90 in Albany, New York sits above 25% of rated New York bridges on inventory load rating (33 t), while its 1958 build year is earlier than 79% of Albany's recorded-year cohort (343 bridges).

RTE I90 in Albany, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1958, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000005513349

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: RTE I90

The RTE I90 bridge in Albany, New York carries RTE I90 over 87IX RTE I87. It was built in 1958, making it 68 years old today. It was last reconstructed in 2014, extending its service life. The structure is built primarily of steel and spans 4 sections, stretching 77.7 meters (255 feet) end to end. Daily traffic averages 11,162 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by State Toll Authority.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How RTE I90 compares

▼ 9.0
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
343
Bridges in Albany · 18 in Poor condition

Age against the county: built in 1958, earlier than 271 of Albany's 343 bridges with a recorded construction year (79%), against a county median build year of 1972. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

RTE I90 32.7 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

RTE I90 vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

33 Top 75% higher than 25% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Albany inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 343 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1958
Last Reconstructed
2014
Material
Steel
Number of Spans
4
Structure Length
77.7 m (255 ft)
Deck Width
27.1 m (89 ft)
Owner
State Toll Authority
Avg Daily Traffic
11,162 vehicles/day
Structure Number
000000005513349

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether RTE I90 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare RTE I90 against other structures in Albany and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE I90?

RTE I90 in Albany, New York has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is RTE I90 inspected?

RTE I90's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,162 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE I90 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE I90?

RTE I90 has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining RTE I90?

RTE I90 is owned and maintained by State Toll Authority.

How old is RTE I90 and does age affect safety?

RTE I90 was built in 1958, making it 68 years old and last reconstructed in 2014.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.