FHWA NBI 2024 Inspection record Public-domain dataset

W. 36TH ST & DYER

Carrying W. 36TH ST & DYER over RTE I495

IN WEST MANHATTAN, New York, New York

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
57 t Inventory load rating Higher than 85% of rated New York bridges

W. 36TH ST & DYER in New York, New York sits above 85% of rated New York bridges on inventory load rating (57 t), while its 1954 build year is earlier than 38% of New York's recorded-year cohort (247 bridges).

W. 36TH ST & DYER in New York, New York is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1954, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure NY:000000005523910

INTERSTATE-ERA · CONCRETE · SINGLE-SPAN · TIED-CTRL · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: W. 36TH ST & DYER

The W. 36TH ST & DYER bridge in New York, New York carries W. 36TH ST & DYER over RTE I495. It was built in 1954, making it 72 years old today. The structure is built primarily of concrete and spans 1 section, stretching 10.1 meters (33 feet) end to end. Daily traffic averages 7,892 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by Local Toll Authority.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How W. 36TH ST & DYER compares

▲ 15.5
Load rating vs New York average (41.7 t; 17,641 of 17,642 rated)
247
Bridges in New York · 24 in Poor condition

Age against the county: built in 1954, earlier than 93 of New York's 247 bridges with a recorded construction year (38%), against a county median build year of 1939. This is one of the newer structures in its county.

W. 36TH ST & DYER 57.2 t
New York average (17,641 of 17,642 rated) 41.7 t

Live comparison across New York bridges with a recorded inventory load rating (17,641 of 17,642 rated).

W. 36TH ST & DYER vs every rated New York bridge

Inventory load rating (metric tons), FHWA NBI, this state

57 Top 15% higher than 85% of 17,641 bridges

rated New York bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
57.2 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

New York inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 247 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1954
Material
Concrete
Number of Spans
1
Structure Length
10.1 m (33 ft)
Deck Width
97.0 m (318 ft)
Owner
Local Toll Authority
Avg Daily Traffic
7,892 vehicles/day
Structure Number
000000005523910

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether W. 36TH ST & DYER is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare W. 36TH ST & DYER against other structures in New York and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for W. 36TH ST & DYER?

W. 36TH ST & DYER in New York, New York has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is W. 36TH ST & DYER inspected?

W. 36TH ST & DYER's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,892 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. W. 36TH ST & DYER is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for W. 36TH ST & DYER?

W. 36TH ST & DYER has an NBI inventory load rating of 57.2 metric tons.

Who is responsible for maintaining W. 36TH ST & DYER?

W. 36TH ST & DYER is owned and maintained by Local Toll Authority.

How old is W. 36TH ST & DYER and does age affect safety?

W. 36TH ST & DYER was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.