FHWA NBI 2024 Inspection record Public-domain dataset

HOOPER ST TR-402

Carrying HOOPER ST TR-402 over USR 33

0.16M E OF SR 682, Athens, Ohio

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
32 t Inventory load rating Lower than 74% of rated Ohio bridges

HOOPER ST TR-402 in Athens, Ohio sits above 26% of rated Ohio bridges on inventory load rating (32 t), while its 1978 build year is earlier than 45% of Athens's recorded-year cohort (309 bridges).

HOOPER ST TR-402 in Athens, Ohio is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1978, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OH:0500917

INTERSTATE-ERA · STEEL · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-GOOD

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: HOOPER ST TR-402

The HOOPER ST TR-402 bridge in Athens, Ohio carries HOOPER ST TR-402 over USR 33. It was built in 1978, making it 48 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 86.3 meters (283 feet) end to end. Daily traffic averages 545 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How HOOPER ST TR-402 compares

▼ 4.7
Load rating vs Ohio average (37.1 t; 26,729 rated)
309
Bridges in Athens · 21 in Poor condition

Age against the county: built in 1978, earlier than 138 of Athens's 309 bridges with a recorded construction year (45%), against a county median build year of 1975. This is one of the newer structures in its county.

HOOPER ST TR-402 32.4 t
Ohio average (26,729 rated) 37.1 t

Live comparison across Ohio bridges with a recorded inventory load rating (26,729 rated).

HOOPER ST TR-402 vs every rated Ohio bridge

Inventory load rating (metric tons), FHWA NBI, this state

32 Top 74% higher than 26% of 26,729 bridges

rated Ohio bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Athens inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 309 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1978
Material
Steel Continuous
Number of Spans
3
Structure Length
86.3 m (283 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
545 vehicles/day
Structure Number
0500917

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether HOOPER ST TR-402 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare HOOPER ST TR-402 against other structures in Athens and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for HOOPER ST TR-402?

HOOPER ST TR-402 in Athens, Ohio has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is HOOPER ST TR-402 inspected?

HOOPER ST TR-402's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 545 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. HOOPER ST TR-402 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for HOOPER ST TR-402?

HOOPER ST TR-402 has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining HOOPER ST TR-402?

HOOPER ST TR-402 is owned and maintained by State Highway Agency.

How old is HOOPER ST TR-402 and does age affect safety?

HOOPER ST TR-402 was built in 1978, making it 48 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.