Fair
42 t Inventory load rating Higher than 70% of rated Ohio bridges

USR 20A in Fulton, Ohio sits above 70% of rated Ohio bridges on inventory load rating (42 t), while its 1932 build year is earlier than 95% of Fulton's recorded-year cohort (198 bridges).

USR 20A in Fulton, Ohio is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1932, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OH:2600722

PRE-1950 · CONCRETE · SINGLE-SPAN · SUB-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: USR 20A

The USR 20A bridge in Fulton, Ohio carries USR 20A over SWAN CREEK. It was built in 1932, making it 94 years old today. It was last reconstructed in 1978, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 11.9 meters (39 feet) end to end. Daily traffic averages 7,987 vehicles, placing it in the moderately-trafficked tier of Ohio bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How USR 20A compares

▲ 5.0
Load rating vs Ohio average (37.1 t; 26,729 rated)
198
Bridges in Fulton

Age against the county: built in 1932, earlier than 188 of Fulton's 198 bridges with a recorded construction year (95%), against a county median build year of 1970. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

USR 20A 42.1 t
Ohio average (26,729 rated) 37.1 t

Live comparison across Ohio bridges with a recorded inventory load rating (26,729 rated).

USR 20A vs every rated Ohio bridge

Inventory load rating (metric tons), FHWA NBI, this state

42 Top 30% higher than 70% of 26,729 bridges

rated Ohio bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
42.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Fulton inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 198 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1932
Last Reconstructed
1978
Material
Concrete
Number of Spans
1
Structure Length
11.9 m (39 ft)
Deck Width
12.0 m (39 ft)
Owner
State Highway Agency
Avg Daily Traffic
7,987 vehicles/day
Structure Number
2600722

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether USR 20A is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare USR 20A against other structures in Fulton and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for USR 20A?

USR 20A in Fulton, Ohio has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is USR 20A inspected?

USR 20A's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,987 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. USR 20A is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for USR 20A?

USR 20A has an NBI inventory load rating of 42.1 metric tons.

Who is responsible for maintaining USR 20A?

USR 20A is owned and maintained by State Highway Agency.

How old is USR 20A and does age affect safety?

USR 20A was built in 1932, making it 94 years old and last reconstructed in 1978.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.