FHWA NBI 2024 Inspection record Public-domain dataset

SNYDER 92

Carrying SNYDER 92 over SNYDER / W BR HURON RVR

0.7 MI E OF S R 99, Huron, Ohio

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
45 t Inventory load rating Higher than 77% of rated Ohio bridges

SNYDER 92 in Huron, Ohio sits above 77% of rated Ohio bridges on inventory load rating (45 t), while its 1900 build year is earlier than 98% of Huron's recorded-year cohort (311 bridges).

SNYDER 92 in Huron, Ohio is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1900, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 8. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OH:3936570

PRE-1950 · CONCRETE · SINGLE-SPAN · SUB-LED · LOCAL-ADT · HEAVY-LOAD · CAT-GOOD

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SNYDER 92

The SNYDER 92 bridge in Huron, Ohio carries SNYDER 92 over SNYDER / W BR HURON RVR. It was built in 1900, making it 126 years old today. It was last reconstructed in 2021, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 28.3 meters (93 feet) end to end. Daily traffic averages 200 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 9/9, superstructure at 9/9, substructure at 8/9. The weakest component sits in good condition. All reported major components score above the Poor range.

How SNYDER 92 compares

▲ 7.6
Load rating vs Ohio average (37.1 t; 26,729 rated)
311
Bridges in Huron · 25 in Poor condition

Age against the county: built in 1900, earlier than 306 of Huron's 311 bridges with a recorded construction year (98%), against a county median build year of 1992. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SNYDER 92 44.7 t
Ohio average (26,729 rated) 37.1 t

Live comparison across Ohio bridges with a recorded inventory load rating (26,729 rated).

SNYDER 92 vs every rated Ohio bridge

Inventory load rating (metric tons), FHWA NBI, this state

45 Top 23% higher than 77% of 26,729 bridges

rated Ohio bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
9/9
Good (7–9)
Superstructure
9/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
44.7 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Huron inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 311 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1900
Last Reconstructed
2021
Material
Concrete
Number of Spans
1
Structure Length
28.3 m (93 ft)
Deck Width
7.3 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
200 vehicles/day
Structure Number
3936570

Condition Analysis

  • The deck (driving surface) is in good condition (9/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates good at 9/9, with no significant deterioration on file.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SNYDER 92 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SNYDER 92 against other structures in Huron and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SNYDER 92?

SNYDER 92 in Huron, Ohio has a deck rating of 9/9, superstructure rating of 9/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is SNYDER 92 inspected?

SNYDER 92's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 200 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SNYDER 92 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SNYDER 92?

SNYDER 92 has an NBI inventory load rating of 44.7 metric tons.

Who is responsible for maintaining SNYDER 92?

SNYDER 92 is owned and maintained by County Highway Agency.

How old is SNYDER 92 and does age affect safety?

SNYDER 92 was built in 1900, making it 126 years old and last reconstructed in 2021.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.