FHWA NBI 2024 Inspection record Public-domain dataset

HENDRICKSON RD C80

Carrying HENDRICKSON RD C80 over I75

.8 MI S OF SR 122, Warren, Ohio

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
26 t Inventory load rating Lower than 88% of rated Ohio bridges

HENDRICKSON RD C80 in Warren, Ohio sits above 12% of rated Ohio bridges on inventory load rating (26 t), while its 1960 build year is earlier than 86% of Warren's recorded-year cohort (336 bridges).

HENDRICKSON RD C80 in Warren, Ohio is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1960, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OH:8303339

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-GOOD

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: HENDRICKSON RD C80

The HENDRICKSON RD C80 bridge in Warren, Ohio carries HENDRICKSON RD C80 over I75. It was built in 1960, making it 66 years old today. It was last reconstructed in 2008, extending its service life. The structure is built primarily of steel continuous and spans 4 sections, stretching 85.6 meters (281 feet) end to end. Daily traffic averages 1,949 vehicles, placing it in the moderately-trafficked tier of Ohio bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How HENDRICKSON RD C80 compares

▼ 11.2
Load rating vs Ohio average (37.1 t; 26,729 rated)
336
Bridges in Warren · 18 in Poor condition

Age against the county: built in 1960, earlier than 289 of Warren's 336 bridges with a recorded construction year (86%), against a county median build year of 1980. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

HENDRICKSON RD C80 25.9 t
Ohio average (26,729 rated) 37.1 t

Live comparison across Ohio bridges with a recorded inventory load rating (26,729 rated).

HENDRICKSON RD C80 vs every rated Ohio bridge

Inventory load rating (metric tons), FHWA NBI, this state

26 Top 88% higher than 12% of 26,729 bridges

rated Ohio bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
25.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Warren inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 336 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1960
Last Reconstructed
2008
Material
Steel Continuous
Number of Spans
4
Structure Length
85.6 m (281 ft)
Deck Width
9.4 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,949 vehicles/day
Structure Number
8303339

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether HENDRICKSON RD C80 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare HENDRICKSON RD C80 against other structures in Warren and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for HENDRICKSON RD C80?

HENDRICKSON RD C80 in Warren, Ohio has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is HENDRICKSON RD C80 inspected?

HENDRICKSON RD C80's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,949 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. HENDRICKSON RD C80 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for HENDRICKSON RD C80?

HENDRICKSON RD C80 has an NBI inventory load rating of 25.9 metric tons.

Who is responsible for maintaining HENDRICKSON RD C80?

HENDRICKSON RD C80 is owned and maintained by State Highway Agency.

How old is HENDRICKSON RD C80 and does age affect safety?

HENDRICKSON RD C80 was built in 1960, making it 66 years old and last reconstructed in 2008.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.