FHWA NBI 2024 Inspection record Public-domain dataset

7236C(COYOTE TRL)

Carrying 7236C(COYOTE TRL) over CREEK

COYOTE TRAIL .1E DIP CRK, Tulsa, Oklahoma

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
12 t Inventory load rating Lower than 95% of rated Oklahoma bridges

7236C(COYOTE TRL) in Tulsa, Oklahoma sits above 5% of rated Oklahoma bridges on inventory load rating (12 t), while its 1920 build year is earlier than 99% of Tulsa's recorded-year cohort (1,135 bridges).

7236C(COYOTE TRL) in Tulsa, Oklahoma is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1920, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OK:008110000000000

PRE-1950 · STEEL · SINGLE-SPAN · SUB-LED · LOCAL-ADT · LIGHT-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 7236C(COYOTE TRL)

The 7236C(COYOTE TRL) bridge in Tulsa, Oklahoma carries 7236C(COYOTE TRL) over CREEK. It was built in 1920, making it 106 years old today. The structure is built primarily of steel and spans 1 section, stretching 7.9 meters (26 feet) end to end. Daily traffic averages 898 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How 7236C(COYOTE TRL) compares

▼ 20.2
Load rating vs Oklahoma average (32.0 t; 22,909 of 22,917 rated)
1,135
Bridges in Tulsa · 65 in Poor condition

Age against the county: built in 1920, earlier than 1,124 of Tulsa's 1,135 bridges with a recorded construction year (99%), against a county median build year of 1978. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

7236C(COYOTE TRL) 11.8 t
Oklahoma average (22,909 of 22,917 rated) 32.0 t

Live comparison across Oklahoma bridges with a recorded inventory load rating (22,909 of 22,917 rated).

7236C(COYOTE TRL) vs every rated Oklahoma bridge

Inventory load rating (metric tons), FHWA NBI, this state

12 Top 95% higher than 5% of 22,909 bridges

rated Oklahoma bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
11.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Tulsa inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,135 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1920
Material
Steel
Number of Spans
1
Structure Length
7.9 m (26 ft)
Deck Width
7.0 m (23 ft)
Owner
County Highway Agency
Avg Daily Traffic
898 vehicles/day
Structure Number
008110000000000

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear on file for this vintage.

How to read this record

7236C(COYOTE TRL) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 7236C(COYOTE TRL) against other structures in Tulsa and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 7236C(COYOTE TRL)?

7236C(COYOTE TRL) in Tulsa, Oklahoma has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is 7236C(COYOTE TRL) inspected?

7236C(COYOTE TRL)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 898 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 7236C(COYOTE TRL) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 7236C(COYOTE TRL)?

7236C(COYOTE TRL) has an NBI inventory load rating of 11.8 metric tons.

Who is responsible for maintaining 7236C(COYOTE TRL)?

7236C(COYOTE TRL) is owned and maintained by County Highway Agency.

How old is 7236C(COYOTE TRL) and does age affect safety?

7236C(COYOTE TRL) was built in 1920, making it 106 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.