FHWA NBI 2024 Inspection record Public-domain dataset

4166C

Carrying 4166C over DRY CREEK

2.2N OF DAVENPORT, Lincoln, Oklahoma

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
22 t Inventory load rating Lower than 74% of rated Oklahoma bridges

4166C in Lincoln, Oklahoma sits above 26% of rated Oklahoma bridges on inventory load rating (22 t), while its 1924 build year is earlier than 96% of Lincoln's recorded-year cohort (450 bridges).

4166C in Lincoln, Oklahoma is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1924, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OK:014050000000000

PRE-1950 · STEEL · SINGLE-SPAN · SUB-LED · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Structural health score

A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.

F
Overall Score
15/100
4166C
Deck Condition F
6/9
NBI deck condition rating (0=failed, 9=excellent)
Superstructure Condition F
5/9
NBI superstructure condition rating (0=failed, 9=excellent)
Substructure Condition F
4/9
NBI substructure condition rating (0=failed, 9=excellent)
Load Rating F
22 t
NBI inventory load rating vs the national corpus

Bridge Snapshot: 4166C

The 4166C bridge in Lincoln, Oklahoma carries 4166C over DRY CREEK. It was built in 1924, making it 102 years old today. The structure is built primarily of steel and spans 1 section, stretching 38.1 meters (125 feet) end to end. Daily traffic averages 75 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection places the weakest component in poor condition (see the full component ratings below). Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How 4166C compares

▼ 10.4
Load rating vs Oklahoma average (32.0 t; 22,909 of 22,917 rated)
450
Bridges in Lincoln · 60 in Poor condition

Age against the county: built in 1924, earlier than 430 of Lincoln's 450 bridges with a recorded construction year (96%), against a county median build year of 1984. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

4166C 21.6 t
Oklahoma average (22,909 of 22,917 rated) 32.0 t

Live comparison across Oklahoma bridges with a recorded inventory load rating (22,909 of 22,917 rated).

4166C vs every rated Oklahoma bridge

Inventory load rating (metric tons), FHWA NBI, this state

22 Top 74% higher than 26% of 22,909 bridges

rated Oklahoma bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
21.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lincoln inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 450 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1924
Material
Steel
Number of Spans
1
Structure Length
38.1 m (125 ft)
Deck Width
7.2 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
75 vehicles/day
Structure Number
014050000000000

Condition Analysis

  • • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.

How to read this record

4166C is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 4166C against other structures in Lincoln and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 4166C?

4166C in Lincoln, Oklahoma has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is 4166C inspected?

4166C's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 75 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 4166C is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 4166C?

4166C has an NBI inventory load rating of 21.6 metric tons.

Who is responsible for maintaining 4166C?

4166C is owned and maintained by County Highway Agency.

How old is 4166C and does age affect safety?

4166C was built in 1924, making it 102 years old.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.