FHWA NBI 2024 Inspection record Public-domain dataset

COLUMBUS ST.

Carrying COLUMBUS ST. over OAK CREEK

014 MILES SOUTH OF ALBANY, Linn, Oregon

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
33 t Inventory load rating Higher than 58% of rated Oregon bridges

COLUMBUS ST. in Linn, Oregon sits above 58% of rated Oregon bridges on inventory load rating (33 t), while its 1958 build year is earlier than 78% of Linn's recorded-year cohort (566 bridges).

COLUMBUS ST. in Linn, Oregon is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1958, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OR:12405 001100146

INTERSTATE-ERA · CONCRETE · LONG-SPAN-RUN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • LONG-SPAN-RUN 4 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: COLUMBUS ST.

The COLUMBUS ST. bridge in Linn, Oregon carries COLUMBUS ST. over OAK CREEK. It was built in 1958, making it 68 years old today. It was last reconstructed in 1991, extending its service life. The structure is built primarily of concrete and spans 4 sections, stretching 30.8 meters (101 feet) end to end. Daily traffic averages 2,987 vehicles, placing it in the moderately-trafficked tier of Oregon bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How COLUMBUS ST. compares

▲ 0.9
Load rating vs Oregon average (31.8 t; 8,282 of 8,305 rated)
566
Bridges in Linn · 100 in Poor condition

Age against the county: built in 1958, earlier than 440 of Linn's 566 bridges with a recorded construction year (78%), against a county median build year of 1967. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

COLUMBUS ST. 32.7 t
Oregon average (8,282 of 8,305 rated) 31.8 t

Live comparison across Oregon bridges with a recorded inventory load rating (8,282 of 8,305 rated).

COLUMBUS ST. vs every rated Oregon bridge

Inventory load rating (metric tons), FHWA NBI, this state

33 Top 42% higher than 58% of 8,282 bridges

rated Oregon bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Linn inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 566 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1958
Last Reconstructed
1991
Material
Concrete
Number of Spans
4
Structure Length
30.8 m (101 ft)
Deck Width
13.0 m (43 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
2,987 vehicles/day
Structure Number
12405 001100146

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

COLUMBUS ST. is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare COLUMBUS ST. against other structures in Linn and across Oregon. Oregon bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for COLUMBUS ST.?

COLUMBUS ST. in Linn, Oregon has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is COLUMBUS ST. inspected?

COLUMBUS ST.'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,987 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. COLUMBUS ST. is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for COLUMBUS ST.?

COLUMBUS ST. has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining COLUMBUS ST.?

COLUMBUS ST. is owned and maintained by City/Municipal Highway Agency.

How old is COLUMBUS ST. and does age affect safety?

COLUMBUS ST. was built in 1958, making it 68 years old and last reconstructed in 1991.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.