FHWA NBI 2024 Inspection record Public-domain dataset

LITTLE VLY RD C6

Carrying LITTLE VLY RD C6 over VALE MAIN CANAL

037 MI E INTER FAS B497, Malheur, Oregon

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
22 t Inventory load rating Lower than 71% of rated Oregon bridges

LITTLE VLY RD C6 in Malheur, Oregon sits above 29% of rated Oregon bridges on inventory load rating (22 t), while its 1978 build year is earlier than 43% of Malheur's recorded-year cohort (181 bridges).

LITTLE VLY RD C6 in Malheur, Oregon is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1978, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OR:45C143069800372

INTERSTATE-ERA · PRESTRESS · SINGLE-SPAN · SUB-LED · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: LITTLE VLY RD C6

The LITTLE VLY RD C6 bridge in Malheur, Oregon carries LITTLE VLY RD C6 over VALE MAIN CANAL. It was built in 1978, making it 48 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 15.2 meters (50 feet) end to end. Daily traffic averages 140 vehicles, placing it in the lower-traffic tier of Oregon bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How LITTLE VLY RD C6 compares

▼ 9.6
Load rating vs Oregon average (31.8 t; 8,282 of 8,305 rated)
181
Bridges in Malheur · 5 in Poor condition

Age against the county: built in 1978, earlier than 78 of Malheur's 181 bridges with a recorded construction year (43%), against a county median build year of 1976. This is one of the newer structures in its county.

LITTLE VLY RD C6 22.2 t
Oregon average (8,282 of 8,305 rated) 31.8 t

Live comparison across Oregon bridges with a recorded inventory load rating (8,282 of 8,305 rated).

LITTLE VLY RD C6 vs every rated Oregon bridge

Inventory load rating (metric tons), FHWA NBI, this state

22 Top 71% higher than 29% of 8,282 bridges

rated Oregon bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
22.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Malheur inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 181 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1978
Material
Prestressed Concrete
Number of Spans
1
Structure Length
15.2 m (50 ft)
Deck Width
7.3 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
140 vehicles/day
Structure Number
45C143069800372

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear on file for this vintage.

How to read this record

LITTLE VLY RD C6 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LITTLE VLY RD C6 against other structures in Malheur and across Oregon. Oregon bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LITTLE VLY RD C6?

LITTLE VLY RD C6 in Malheur, Oregon has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LITTLE VLY RD C6 inspected?

LITTLE VLY RD C6's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 140 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LITTLE VLY RD C6 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LITTLE VLY RD C6?

LITTLE VLY RD C6 has an NBI inventory load rating of 22.2 metric tons.

Who is responsible for maintaining LITTLE VLY RD C6?

LITTLE VLY RD C6 is owned and maintained by County Highway Agency.

How old is LITTLE VLY RD C6 and does age affect safety?

LITTLE VLY RD C6 was built in 1978, making it 48 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.