FHWA NBI 2024 Inspection record Public-domain dataset

LARIMER AV

Carrying LARIMER AV over WASHINGTON BLVD (RT 8)

047 Larimer Ave over Wash, Allegheny, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
31 t Inventory load rating Lower than 77% of rated Pennsylvania bridges

LARIMER AV in Allegheny, Pennsylvania sits above 23% of rated Pennsylvania bridges on inventory load rating (31 t), while its 1912 build year is earlier than 95% of Allegheny's recorded-year cohort (1,294 bridges).

LARIMER AV in Allegheny, Pennsylvania is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1912, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000002419

PRE-1950 · CONCRETE · SINGLE-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: LARIMER AV

The LARIMER AV bridge in Allegheny, Pennsylvania carries LARIMER AV over WASHINGTON BLVD (RT 8). It was built in 1912, making it 114 years old today. It was last reconstructed in 1979, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 167.0 meters (548 feet) end to end. Daily traffic averages 8,000 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How LARIMER AV compares

▼ 7.6
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
1,294
Bridges in Allegheny · 115 in Poor condition

Age against the county: built in 1912, earlier than 1,229 of Allegheny's 1,294 bridges with a recorded construction year (95%), against a county median build year of 1968. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

LARIMER AV 30.8 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

LARIMER AV vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

31 Top 77% higher than 23% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
30.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Allegheny inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,294 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1912
Last Reconstructed
1979
Material
Concrete
Number of Spans
1
Structure Length
167.0 m (548 ft)
Deck Width
14.0 m (46 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
8,000 vehicles/day
Structure Number
000000000002419

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.

How to read this record

LARIMER AV is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LARIMER AV against other structures in Allegheny and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LARIMER AV?

LARIMER AV in Allegheny, Pennsylvania has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LARIMER AV inspected?

LARIMER AV's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 8,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LARIMER AV is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LARIMER AV?

LARIMER AV has an NBI inventory load rating of 30.8 metric tons.

Who is responsible for maintaining LARIMER AV?

LARIMER AV is owned and maintained by City/Municipal Highway Agency.

How old is LARIMER AV and does age affect safety?

LARIMER AV was built in 1912, making it 114 years old and last reconstructed in 1979.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.