FHWA NBI 2024 Inspection record Public-domain dataset

SR 3014-US 322 BUS

Carrying SR 3014-US 322 BUS over SR 99 - I 99

ATHERTON ST INTERCHANGE, Centre, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
35 t Inventory load rating Lower than 60% of rated Pennsylvania bridges

SR 3014-US 322 BUS in Centre, Pennsylvania sits above 40% of rated Pennsylvania bridges on inventory load rating (35 t), while its 1971 build year is earlier than 63% of Centre's recorded-year cohort (367 bridges).

SR 3014-US 322 BUS in Centre, Pennsylvania is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1971, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000009722

INTERSTATE-ERA · STEEL · MULTI-SPAN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 3014-US 322 BUS

The SR 3014-US 322 BUS bridge in Centre, Pennsylvania carries SR 3014-US 322 BUS over SR 99 - I 99. It was built in 1971, making it 55 years old today. The structure is built primarily of steel continuous and spans 2 sections, stretching 93.9 meters (308 feet) end to end. Daily traffic averages 6,324 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How SR 3014-US 322 BUS compares

▼ 3.9
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
367
Bridges in Centre · 22 in Poor condition

Age against the county: built in 1971, earlier than 233 of Centre's 367 bridges with a recorded construction year (63%), against a county median build year of 1992. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SR 3014-US 322 BUS 34.5 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

SR 3014-US 322 BUS vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 60% higher than 40% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
34.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Centre inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 367 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1971
Material
Steel Continuous
Number of Spans
2
Structure Length
93.9 m (308 ft)
Deck Width
13.2 m (43 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,324 vehicles/day
Structure Number
000000000009722

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 3014-US 322 BUS is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 3014-US 322 BUS against other structures in Centre and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 3014-US 322 BUS?

SR 3014-US 322 BUS in Centre, Pennsylvania has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is SR 3014-US 322 BUS inspected?

SR 3014-US 322 BUS's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,324 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 3014-US 322 BUS is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 3014-US 322 BUS?

SR 3014-US 322 BUS has an NBI inventory load rating of 34.5 metric tons.

Who is responsible for maintaining SR 3014-US 322 BUS?

SR 3014-US 322 BUS is owned and maintained by State Highway Agency.

How old is SR 3014-US 322 BUS and does age affect safety?

SR 3014-US 322 BUS was built in 1971, making it 55 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.