FHWA NBI 2024 Inspection record Public-domain dataset

SR 4003

Carrying SR 4003 over DUNLAP CREEK

BROWNSVILLE BOROUGH, Fayette, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
31 t Inventory load rating Lower than 77% of rated Pennsylvania bridges

SR 4003 in Fayette, Pennsylvania sits above 23% of rated Pennsylvania bridges on inventory load rating (31 t), while its 1839 build year is earlier than 100% of Fayette's recorded-year cohort (422 bridges).

SR 4003 in Fayette, Pennsylvania is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1839, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000016958

PRE-1950 · MAT-OTHER · SINGLE-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • MAT-OTHER Other
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 4003

The SR 4003 bridge in Fayette, Pennsylvania carries SR 4003 over DUNLAP CREEK. It was built in 1839, making it 187 years old today. It was last reconstructed in 1981, extending its service life. The structure is built primarily of aluminum/iron and spans 1 section, stretching 25.6 meters (84 feet) end to end. Daily traffic averages 6,197 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How SR 4003 compares

▼ 7.6
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
422
Bridges in Fayette · 75 in Poor condition

Age against the county: built in 1839, earlier than 421 of Fayette's 422 bridges with a recorded construction year (100%), against a county median build year of 1971. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SR 4003 30.8 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

SR 4003 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

31 Top 77% higher than 23% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
30.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Fayette inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 422 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1839
Last Reconstructed
1981
Material
Aluminum/Iron
Number of Spans
1
Structure Length
25.6 m (84 ft)
Deck Width
11.3 m (37 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,197 vehicles/day
Structure Number
000000000016958

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

SR 4003 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 4003 against other structures in Fayette and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 4003?

SR 4003 in Fayette, Pennsylvania has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SR 4003 inspected?

SR 4003's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,197 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 4003 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 4003?

SR 4003 has an NBI inventory load rating of 30.8 metric tons.

Who is responsible for maintaining SR 4003?

SR 4003 is owned and maintained by State Highway Agency.

How old is SR 4003 and does age affect safety?

SR 4003 was built in 1839, making it 187 years old and last reconstructed in 1981.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.