FHWA NBI 2024 Inspection record Public-domain dataset

PA 283 EB; SR 0300

Carrying PA 283 EB; SR 0300 over LANC.CO.PARK TRAIL

1/4 MI. E. OF CONEWAGO CR, Lancaster, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
29 t Inventory load rating Lower than 81% of rated Pennsylvania bridges

PA 283 EB; SR 0300 in Lancaster, Pennsylvania sits above 19% of rated Pennsylvania bridges on inventory load rating (29 t), while its 1968 build year is earlier than 61% of Lancaster's recorded-year cohort (801 bridges).

PA 283 EB; SR 0300 in Lancaster, Pennsylvania is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1968, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000021162

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · SUPER-LED · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • SUPER-LED Superstructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: PA 283 EB; SR 0300

The PA 283 EB; SR 0300 bridge in Lancaster, Pennsylvania carries PA 283 EB; SR 0300 over LANC.CO.PARK TRAIL. It was built in 1968, making it 58 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 39.9 meters (131 feet) end to end. Daily traffic averages 21,988 vehicles, placing it in the heavily-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How PA 283 EB; SR 0300 compares

▼ 9.4
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
801
Bridges in Lancaster · 90 in Poor condition

Age against the county: built in 1968, earlier than 486 of Lancaster's 801 bridges with a recorded construction year (61%), against a county median build year of 1972. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

PA 283 EB; SR 0300 29.0 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

PA 283 EB; SR 0300 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

29 Top 81% higher than 19% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
29.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lancaster inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 801 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1968
Material
Prestressed Concrete
Number of Spans
3
Structure Length
39.9 m (131 ft)
Deck Width
13.4 m (44 ft)
Owner
State Highway Agency
Avg Daily Traffic
21,988 vehicles/day
Structure Number
000000000021162

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether PA 283 EB; SR 0300 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PA 283 EB; SR 0300 against other structures in Lancaster and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PA 283 EB; SR 0300?

PA 283 EB; SR 0300 in Lancaster, Pennsylvania has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is PA 283 EB; SR 0300 inspected?

PA 283 EB; SR 0300's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 21,988 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PA 283 EB; SR 0300 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PA 283 EB; SR 0300?

PA 283 EB; SR 0300 has an NBI inventory load rating of 29.0 metric tons.

Who is responsible for maintaining PA 283 EB; SR 0300?

PA 283 EB; SR 0300 is owned and maintained by State Highway Agency.

How old is PA 283 EB; SR 0300 and does age affect safety?

PA 283 EB; SR 0300 was built in 1968, making it 58 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.