FHWA NBI 2024 Inspection record Public-domain dataset

PA 772; SR 0772

Carrying PA 772; SR 0772 over CAT TAIL RUN

2 MI S.E. OF INTERCOURSE, Lancaster, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
33 t Inventory load rating Lower than 73% of rated Pennsylvania bridges

PA 772; SR 0772 in Lancaster, Pennsylvania sits above 27% of rated Pennsylvania bridges on inventory load rating (33 t), while its 1956 build year is earlier than 72% of Lancaster's recorded-year cohort (801 bridges).

PA 772; SR 0772 in Lancaster, Pennsylvania is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1956, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000021339

INTERSTATE-ERA · CONCRETE · SINGLE-SPAN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: PA 772; SR 0772

The PA 772; SR 0772 bridge in Lancaster, Pennsylvania carries PA 772; SR 0772 over CAT TAIL RUN. It was built in 1956, making it 70 years old today. It was last reconstructed in 1978, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 8.2 meters (27 feet) end to end. Daily traffic averages 6,460 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How PA 772; SR 0772 compares

▼ 5.7
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
801
Bridges in Lancaster · 90 in Poor condition

Age against the county: built in 1956, earlier than 574 of Lancaster's 801 bridges with a recorded construction year (72%), against a county median build year of 1972. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

PA 772; SR 0772 32.7 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

PA 772; SR 0772 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

33 Top 73% higher than 27% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lancaster inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 801 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1956
Last Reconstructed
1978
Material
Concrete
Number of Spans
1
Structure Length
8.2 m (27 ft)
Deck Width
10.8 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,460 vehicles/day
Structure Number
000000000021339

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether PA 772; SR 0772 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PA 772; SR 0772 against other structures in Lancaster and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PA 772; SR 0772?

PA 772; SR 0772 in Lancaster, Pennsylvania has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is PA 772; SR 0772 inspected?

PA 772; SR 0772's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,460 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PA 772; SR 0772 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PA 772; SR 0772?

PA 772; SR 0772 has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining PA 772; SR 0772?

PA 772; SR 0772 is owned and maintained by State Highway Agency.

How old is PA 772; SR 0772 and does age affect safety?

PA 772; SR 0772 was built in 1956, making it 70 years old and last reconstructed in 1978.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.