FHWA NBI 2024 Inspection record Public-domain dataset

SR 1011 PIERCE ST

Carrying SR 1011 PIERCE ST over SUSQUEHANNA RIVER

WILKES BARRE 548N SR2004, Luzerne, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
26 t Inventory load rating Lower than 86% of rated Pennsylvania bridges

SR 1011 PIERCE ST in Luzerne, Pennsylvania sits above 14% of rated Pennsylvania bridges on inventory load rating (26 t), while its 1979 build year is earlier than 37% of Luzerne's recorded-year cohort (457 bridges).

SR 1011 PIERCE ST in Luzerne, Pennsylvania is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1979, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000023973

INTERSTATE-ERA · PRESTRESS · LONG-SPAN-RUN · TIED-CTRL · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 12 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 1011 PIERCE ST

The SR 1011 PIERCE ST bridge in Luzerne, Pennsylvania carries SR 1011 PIERCE ST over SUSQUEHANNA RIVER. It was built in 1979, making it 47 years old today. It was last reconstructed in 2014, extending its service life. The structure is built primarily of prestressed concrete and spans 12 sections, stretching 350.5 meters (1150 feet) end to end. Daily traffic averages 13,624 vehicles, placing it in the heavily-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How SR 1011 PIERCE ST compares

▼ 12.1
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
457
Bridges in Luzerne · 117 in Poor condition

Age against the county: built in 1979, earlier than 170 of Luzerne's 457 bridges with a recorded construction year (37%), against a county median build year of 1966. This is one of the newer structures in its county.

SR 1011 PIERCE ST 26.3 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

SR 1011 PIERCE ST vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

26 Top 86% higher than 14% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
26.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Luzerne inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 457 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1979
Last Reconstructed
2014
Material
Prestressed Concrete
Number of Spans
12
Structure Length
350.5 m (1150 ft)
Deck Width
24.5 m (80 ft)
Owner
State Highway Agency
Avg Daily Traffic
13,624 vehicles/day
Structure Number
000000000023973

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 1011 PIERCE ST is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 1011 PIERCE ST against other structures in Luzerne and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 1011 PIERCE ST?

SR 1011 PIERCE ST in Luzerne, Pennsylvania has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SR 1011 PIERCE ST inspected?

SR 1011 PIERCE ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 13,624 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 1011 PIERCE ST is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 1011 PIERCE ST?

SR 1011 PIERCE ST has an NBI inventory load rating of 26.3 metric tons.

Who is responsible for maintaining SR 1011 PIERCE ST?

SR 1011 PIERCE ST is owned and maintained by State Highway Agency.

How old is SR 1011 PIERCE ST and does age affect safety?

SR 1011 PIERCE ST was built in 1979, making it 47 years old and last reconstructed in 2014.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.