FHWA NBI 2024 Inspection record Public-domain dataset

ON TSR 601

Carrying ON TSR 601 over FOSTER BROOK

FOSTER BROOK, McKean, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
15 t Inventory load rating Lower than 95% of rated Pennsylvania bridges

ON TSR 601 in McKean, Pennsylvania sits above 5% of rated Pennsylvania bridges on inventory load rating (15 t), while its 1960 build year is earlier than 70% of McKean's recorded-year cohort (226 bridges).

ON TSR 601 in McKean, Pennsylvania is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1960, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000025566

INTERSTATE-ERA · PRESTRESS · SINGLE-SPAN · SUPER-LED · ARTERIAL-ADT · LIGHT-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: ON TSR 601

The ON TSR 601 bridge in McKean, Pennsylvania carries ON TSR 601 over FOSTER BROOK. It was built in 1960, making it 66 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 18.3 meters (60 feet) end to end. Daily traffic averages 7,564 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How ON TSR 601 compares

▼ 23.0
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
226
Bridges in McKean · 42 in Poor condition

Age against the county: built in 1960, earlier than 159 of McKean's 226 bridges with a recorded construction year (70%), against a county median build year of 1986. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

ON TSR 601 15.4 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

ON TSR 601 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

15 Top 95% higher than 5% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
15.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

McKean inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 226 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1960
Material
Prestressed Concrete
Number of Spans
1
Structure Length
18.3 m (60 ft)
Deck Width
14.9 m (49 ft)
Owner
State Highway Agency
Avg Daily Traffic
7,564 vehicles/day
Structure Number
000000000025566

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether ON TSR 601 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ON TSR 601 against other structures in McKean and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ON TSR 601?

ON TSR 601 in McKean, Pennsylvania has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is ON TSR 601 inspected?

ON TSR 601's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,564 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ON TSR 601 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ON TSR 601?

ON TSR 601 has an NBI inventory load rating of 15.4 metric tons.

Who is responsible for maintaining ON TSR 601?

ON TSR 601 is owned and maintained by State Highway Agency.

How old is ON TSR 601 and does age affect safety?

ON TSR 601 was built in 1960, making it 66 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.