FHWA NBI 2024 Inspection record Public-domain dataset

SR 4008

Carrying SR 4008 over SILVER CREEK

FRANKLIN TWP .2M W TR 29, Susquehanna, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
14 t Inventory load rating Lower than 96% of rated Pennsylvania bridges

SR 4008 in Susquehanna, Pennsylvania sits above 4% of rated Pennsylvania bridges on inventory load rating (14 t), while its 1934 build year is earlier than 86% of Susquehanna's recorded-year cohort (284 bridges).

SR 4008 in Susquehanna, Pennsylvania is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1934, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 3. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000032657

PRE-1950 · STEEL · SINGLE-SPAN · DECK-LED · LOCAL-ADT · LIGHT-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • DECK-LED Deck-led
  • LOCAL-ADT Local ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 4008

The SR 4008 bridge in Susquehanna, Pennsylvania carries SR 4008 over SILVER CREEK. It was built in 1934, making it 92 years old today. It was last reconstructed in 1958, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 7.3 meters (24 feet) end to end. Daily traffic averages 391 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How SR 4008 compares

▼ 24.8
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
284
Bridges in Susquehanna · 54 in Poor condition

Age against the county: built in 1934, earlier than 245 of Susquehanna's 284 bridges with a recorded construction year (86%), against a county median build year of 1962. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SR 4008 13.6 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

SR 4008 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

14 Top 96% higher than 4% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
13.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Susquehanna inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 284 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1934
Last Reconstructed
1958
Material
Steel
Number of Spans
1
Structure Length
7.3 m (24 ft)
Deck Width
7.5 m (25 ft)
Owner
State Highway Agency
Avg Daily Traffic
391 vehicles/day
Structure Number
000000000032657

Condition Analysis

  • At 3/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

SR 4008 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 4008 against other structures in Susquehanna and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 4008?

SR 4008 in Susquehanna, Pennsylvania has a deck rating of 3/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is SR 4008 inspected?

SR 4008's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 391 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 4008 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 4008?

SR 4008 has an NBI inventory load rating of 13.6 metric tons.

Who is responsible for maintaining SR 4008?

SR 4008 is owned and maintained by State Highway Agency.

How old is SR 4008 and does age affect safety?

SR 4008 was built in 1934, making it 92 years old and last reconstructed in 1958.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.